001 Hak Akses (open/membership)membership
700 Entri Tambahan Nama OrangIdrus Alwi, promotor; Jusuf Rachmat, co-promotor; Aulia Jusuf, examiner; Suhendro, examiner; Sudigdo Sastroasmoro, examiner; Liem, Isabella Kurnia, examiner; Siagian, Minarma, examiner; Puruhito, examiner
336 Content Typetext (rdacontent)
264b Nama PenerbitFakultas Kedokteran Universitas Indonesia
710 Entri Tambahan Badan KorporasiUniversitas Indonesia. Fakultas Kedokteran
049 No. Barkod07-23-31407116
504 Catatan Bibliografipages 111-119
852 LokasiPerpustakaan UI
338 Carrier Typeonline resource (rdcarrier)
590 Cat. Sumber Pengadaan Koleksi;;
903 Stock Opname
Tahun Buka Akses2023
053 No. Induk07-23-31407116
653 Kata Kuncikatup mekanik; left ventricle reverse remodeling; penyakit katup jantung; strip tunggal perikard
040 Sumber PengataloganLibUI ind rda
245 Judul UtamaLuaran Penggunaan Strip Tunggal Perikardium dan Katup Mekanik dalam Penggantian Katup Aorta: Kajian terhadap Left Ventricle Reverse Remodeling, Six Minute Walking Test dan Soluble Suppression of Tumorigenicity-2 = Outcome of Single-Strip Pericardium and Mechanical Valve in Aortic Valve Replacement: Study on Left Ventricle Reverse Remodeling, Six Minute Walking Test and Soluble Suppression of Tumorigenicity-2
264c Tahun Terbit2022
650 Subyek TopikAortic valve--Transplantation; Heart valve prosthesis
850 Lembaga PemilikUniversitas Indonesia
520 Ringkasan/Abstrak/IntisariPenggantian katup aorta dengan katup mekanik memerlukan biaya mahal, meningkatkan risiko endokarditis dan tromboemboli, serta memerlukan antikoagulan seumur hidup. Perikardium autolog merupakan alternatif untuk penggantian katup aorta. Tujuan penelitian ini adalah membandingkan luaran penggantian katup aorta antara katup mekanik dan perikardium autolog dengan teknik strip tunggal perikardium. Penelitian ini merupakan uji klinis terandomisasi di Pelayanan Jantung Terpadu Rumah Sakit Cipto Mangunkusumo (PJT-RSCM). Subjek dibagi ke dalam 2 kelompok berdasarkan jenis katup yang diterima, yaitu katup mekanik (kelompok mekanik) dan strip perikardium (kelompok strip). Luaran left ventricular reverse remodeling (LVRR), 6 minute walking test (6MWT), dan kadar soluble suppression of tumorigenicity-2 (sST-2) diperiksa preoperasi, 3 bulan, dan 6 bulan pascabedah. Terdapat 34 subjek yang ikut serta dari Juli 2016-Februari 2022, 17 subjek pada masing-masing kelompok. Tidak terdapat beda kejadian LVRR pada kedua kelompok, yaitu 26,7% pada kelompok mekanik dan 29,4% pada kelompok strip (p = 0,703). Pada pemeriksaan jarak 6 minute walking test (6MWT) tidak terdapat perbedaan bermakna jarak 6MWT antara kelompok strip perikardium dan kelompok mekanik pada 6 bulan pascabedah, yaitu 431,93 (SB 93,41) m vs. 404,28 (SB 79,25) m, p = 0,427 pascabedah. Kadar sST-2 kelompok mekanik 16,12 (SB 5,92) pg/mL secara bermakna lebih tinggi dibandingkan kelompok strip 11,52 (SB 6,96) pg/mL, p = 0,023) pada 6 bulan pascabedah. Disimpulkan teknik strip tunggal perikardium memiliki luaran yang sebanding dengan katup mekanik sehingga dapat digunakan sebagai alternatif penggantian katup aorta. ......Aortic valve replacement with mechanical valves are quite expensive, increased the risk of adverse events such as endocarditis and thromboembolism, and requires patients to take anticoagulants for the rest of their life. Autologous pericardium is an alternative for aortic valve replacement. This study aims to compare outcomes of aortic valve replacement using mechanical valve and prosthetic valve with single-strip pericardium technique. This was a randomized clinical trial conducted at the Cipto Mangunkusumo Hospital (PJT-RSCM). Eligible subjects were randomized to either receive mechanical valve (mechanical group) or single-strip pericardium (single-strip group). Outcome assessments of left ventricular reverse remodeling (LVRR), 6 minute walking test (6MWT), and soluble suppression of tumorogenicity-2 (sST-2) were carried out at preoperation, 3 months, and 6 months postoperation. There were 34 subjects recruited from July 2016 to February 2022, 17 subjects in each groups. There was no difference in postoperative LVRR incidence between both groups, 26.7% in mechanical group vs. 29.4% in single strip group (p = 0.703). There was no significant difference of 6MWT between the mechanical and pericardial strip at six months post-operation, 404.28 (SD 79.25) m vs. 431.93 (SD 93.41) m, p = 0.427. The sST-2 level is significantly higher in mechanical group 16.12 (SD 5.92) pg/mL compared to single strip group 11.52 (SD 6.96) pg/mL, p = 0.023 at six months post-operation. We concluded that single strip pericardium technique showed comparable outcomes to mechanical valve and is considered a feasible alternative for aortic valve replacement.
904b Pemeriksa Lembar Kerja
090 No. Panggil SetempatD-pdf
d-Entri Utama Nama Orang
500 Catatan UmumTidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris untuk dipersiapkan terbit pada Jurnal Internasional yaitu The Thoracic and Cardiovascular Surgeon yang diprediksi akan dipublikasikan pada bulan Juni tahun 2023
d-Entri Tambahan Nama Orang
337 Media Typecomputer (rdamedia)
526 Catatan Informasi Program StudiIlmu Kedokteran
100 Entri Utama Nama OrangIsmail, author
264a Kota TerbitJakarta
300 Deskripsi Fisikxxiv, 119 pages : illustration + appendix
904a Pengisi Lembar KerjaTanti-Agustus2023
Akses Naskah Ringkas
856 Akses dan Lokasi Elektronik
502 Catatan Jenis KaryaDisertasi
041 Kode Bahasaind