001 Hak Akses (open/membership) | membership |
700 Entri Tambahan Nama Orang | Andi Ade Wijaya Ramlan, supervisor; Sidharta Kusuma Manggala, supervisor; Achmad Kemal Harzif, supervisor; Zuswayudha Samsu, examiner; Dita Aditianingsih, examiner; Rudyanto Sedono, examiner; Calcarina Fitri Retno W, examiner |
336 Content Type | text (rdacontent) |
264b Nama Penerbit | Fakultas Kedokteran Universitas Indonesia |
710 Entri Tambahan Badan Korporasi | Universitas Indonesia. Fakultas Kedokteran |
504 Catatan Bibliografi | pages 64-67 |
049 No. Barkod | 21-25-03419575 |
852 Lokasi | Perpustakaan UI |
338 Carrier Type | online resource (rdacarrier) |
590 Cat. Sumber Pengadaan Koleksi | |
903 Stock Opname | |
534 Catatan Versi Asli | |
Tahun Buka Akses | 2025 |
053 No. Induk | 21-25-03419575 |
653 Kata Kunci | Distribusi udara paru; EIT; hipertensi intra-abdomen; laparoskopi |
040 Sumber Pengatalogan | LibUI ind rda |
245 Judul Utama | Penggunaan Electrical Impedance Tomography sebagai Panduan Perubahan PEEP pada Pasien Model Hipertensi Intra-Abdomen dalam Mencegah Cedera Epitel Paru: Kajian terhadap Distribusi Ventilasi Paru dan Kadar Penanda RAGE = Electrical Impedance Tomography as a Guide to PEEP Changes in Intra-Abdominal Hypertension Model Patients in Determining Pulmonary Epithelial Injury: Study of Lung Ventilation Distribution and RAGE Marker Levels |
650 Subyek Topik | Respirators (Medical equipment); Laparostomy |
264c Tahun Terbit | 2024 |
850 Lembaga Pemilik | Universitas Indonesia |
520 Ringkasan/Abstrak/Intisari | Latar Belakang: Hipertensi intra-abdomen adalah kondisi yang sering dialami pasien kritis. Untuk memperbaiki distribusi ventilasi paru, pengaturan positive end expiratory pressure (PEEP) pada ventilasi mekanis yang dipandu alat electrical impedance tomography (EIT) dapat digunakan untuk mencegah terjadinya cedera epitel yang ditandai dengan peningkatan kadar receptor for advanced glycation receptor (RAGE) akibat pemberian PEEP yang tidak sesuai.
Metode: Penelitian kohort prospektif dengan metode non probability sampling pada pasien laparoskopi ginekologi. Pasien diberikan manajemen ventilasi sesuai protokol penelitian dengan memberikan PEEP 5-8-11-14 cmH2O pasca insuflasi gas CO2. Distribusi udara diamati melalui alat EIT serta dilakukan pengambilan sampel RAGE melalui bilasan bronkus pada waktu sebelum insuflasi, setelah manajemen ventilasi dan 2 jam pascamanajemen ventilasi.
Hasil: Terdapat perubahan yang bermakna secara statistik pada parameter tidal impedance variation regional (?TIV-ROI) paru dependen (p < 0.001).
Kesimpulan: Alat EIT dapat membantu melihat distribusi udara paru selama pemberian manajemen ventilasi pasien model hipertensi intra-abdomen sehingga tidak menyebabkan cedera pada paru.
......Background: Intra-abdominal hypertension is a condition often experienced by critical patients. To improve the distribution of pulmonary ventilation, positive end expiratory pressure (PEEP) setting in mechanical ventilation guided by an electrical impedance tomography (EIT) device can be used to prevent epithelial injury which is characterized by increased levels of the receptor for advanced glycation receptor (RAGE) due to unsuitable PEEP.
Methods: Prospective cohort study with non-probability sampling method in gynecological laparoscopic patients was conducted. Patients were given ventilation management according to the research protocol by providing PEEP 5-8-11-14 cmH2O after CO2 gas insufflation. Air distribution was observed using the EIT device and RAGE samples were taken via bronchial lavage before insufflation, after ventilation management and 2 hours after ventilation management.
Results: There was a statistically significant change in the dependent lung regional tidal impedance variation (?TIV-ROI) parameter (p < 0.001).
Conclusion: The EIT device aids in monitoring the distribution of lung air during ventilation management for patients with intra-abdominal hypertension to avoid lung injury. |
904b Pemeriksa Lembar Kerja | |
090 No. Panggil Setempat | SP-pdf |
d-Entri Utama Nama Orang | Fildza Sasri Peddyandhari, author |
500 Catatan Umum | Tidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris untuk dipersiapkan terbit pada Jurnal Internasional yaitu Physiological Measurement yang diprediksi akan dipublikasikan pada bulan Juni tahun 2025 |
337 Media Type | computer (rdamedia) |
d-Entri Tambahan Nama Orang | Andi Ade Wijaya Ramlan ; Achmad Kemal Harzif ; Belum Terdaftar |
526 Catatan Informasi Program Studi | Anestesiologi dan Terapi Intensif |
100 Entri Utama Nama Orang | Fildza Sasri Peddyandhari, author |
264a Kota Terbit | Jakarta |
300 Deskripsi Fisik | xv, 67, ilustration + appendix |
904a Pengisi Lembar Kerja | Safna Novia Mahiswari-Januari2025 |
Akses Naskah Ringkas | |
856 Akses dan Lokasi Elektronik | |
502 Catatan Jenis Karya | Spesialis |
041 Kode Bahasa | ind |