001 Hak Akses (open/membership) | membership |
700 Entri Tambahan Nama Orang | Haryoto Kusnoputranto, promotor; Bambang Wispriyono, co-promotor; Laila Fitria, co-promotor; Umar Fahmi Achmadi, examiner; Mondastri Korib Sudaryo, examiner; H.J. Mukono, examiner; Syafruddin, examiner |
336 Content Type | text (rdacontent) |
264b Nama Penerbit | Fakultas Kesehatan Masyarakat Universitas Indonesia |
710 Entri Tambahan Badan Korporasi | Universitas Indonesia. Fakultas Kesehatan Masyarakat |
049 No. Barkod | 07-24-84301811 |
504 Catatan Bibliografi | pages 227-245 |
852 Lokasi | Perpustakaan UI |
338 Carrier Type | online resource (rdacarrier) |
590 Cat. Sumber Pengadaan Koleksi | ;;; |
903 Stock Opname | |
534 Catatan Versi Asli | |
Tahun Buka Akses | 2024 |
053 No. Induk | 07-24-84301811 |
653 Kata Kunci | hipertensi; pm2; stress oksidatif; sitokin inflamasi; multilevel |
040 Sumber Pengatalogan | LibUI ind rda |
245 Judul Utama | Model Pengaruh Pajanan PM2,5 di Udara Ambien terhadap Kejadian Hipertensi melalui Stress Oksidatif dan Sitokin Inflamasi pada Penduduk di Jakarta Pusat = The Influence Model of Ambient Air PM2,5 Exposure with Hypertension through Oxidative Stress and Inflammatory Cytokines among residents in Central Jakarta |
264c Tahun Terbit | 2024 |
650 Subyek Topik | Air?Pollution?Health aspects?Indonesia; Hypertension?Environmental aspects; Oxidative stress?Health aspects; Air quality?Health aspects?Indonesia?Jakarta; Cytokines?Physiological effect |
850 Lembaga Pemilik | Universitas Indonesia |
520 Ringkasan/Abstrak/Intisari | Hipertensi merupakan salah satu kondisi medis yang cukup serius karena dapat meningkatkan risiko penyakit jantung, otak, ginjal dan penyakit lainnya. Wilayah di DKI Jakarta dengan prevalensi hipertensi tertinggi berdasarkan diagnosis dokter yaitu Kota Jakarta Pusat sebesar 12,16%. Partikulat meter organik dan komponen partikulat meter dapat memicu proinflammatory effects pada paru-paru karena kemampuannya mengakibatkan stress oksidatif. Penelitian ini bertujuan untuk menyusun model pengaruh pajanan PM2,5 di udara ambien terhadap kejadian hipertensi melalui stress oksidatif dan sitokin inflamasi pada penduduk di Jakarta Pusat. Penelitian dilakukan pada penduduk dewasa (18-65 tahun) di Kota Jakarta Pusat dengan disain studi hybrid cross sectional ecology. Pengumpulan data secara cluster random sampling dengan analisis data dilakukan melalui pemodelan regresi logistik multilevel dan cox regresi proporsional hazard.
Hasil analisis menunjukkan terdapat asosiasi antara PM2,5 di udara ambien dengan biomarker stress oksidatif (IOR PM2,5: 2,185173-2,185176) dan dengan biomarker sitokin inflamasi (IOR PM2,5: 1,21-1,91). Pemodelan multivariat dengan cox regresi proporsional hazard menunjukkan bahwa variabel umur dan indeks massa tubuh merupakan confounder hubungan antara stress oksidatif dengan hipertensi dan antara sitokin inflamasi dengan hipertensi dengan nilai Rasio Prevalens adjusted (95% CI) masing-masing sebesar 1,19 (0,69-2,03) dan 0,99 (0,58-1,72). Dapat disimpulkan bahwa variabel konsentrasi PM2,5 di udara ambien memiliki peran terhadap terjadinya hipertensi, stress oksidatif dan sitokin inflamasi pada penduduk di Jakarta Pusat.
......Hypertension is a serious medical condition that can increase the risk of heart, brain, kidney and other diseases. The area in DKI Jakarta with the highest prevalence of hypertension based on doctor diagnosis is Central Jakarta city about 12.16%. Organic particulate matters and particulate matter components can trigger proinflammatory efects in the lung due to their ability to cause oxidative stress. This study aims to develop a model of the Influence of PM2,5 Exposure in Ambient Air on Hypertension Occurrence through Oxidative Stress and Inflammatory Cytokines among residents in Central Jakarta. The study was conducted among adult residents (age 18-65 years) in Central Jakarta with hybrid cross sectional study design. Data collected using cluster random sampling with data analysis carried out through multilevel logistic regression modeling and cox proportional hazard regression.
Results show there is an association between PM2.5 in ambient air with oxidative stress biomarkers (IOR PM2.5: 2.185173-2.185176) and with inflammatory cytokine biomarkers (IOR PM2.5: 1.21-1.91). Multivariate modeling with Cox regression proportional hazard shows that age and body mass index are confounders of the relationship between oxidative stress with hypertension and between inflammatory cytokines with hypertension with an adjusted prevalence ratio (95% CI) value of 1.19 (0.69-2.03) and 0.99 (0.58-1.72). It can conclude that concentration of PM2.5 in ambient air has a role on hypertension, oxidative stress and inflammatory cytokine among residents in Central Jakarta. |
904b Pemeriksa Lembar Kerja | |
090 No. Panggil Setempat | D-pdf |
d-Entri Utama Nama Orang | |
500 Catatan Umum | Tidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris untuk dipersiapkan terbit pada Jurnal Internasional yaitu Journal of Preventive Medicine and Public Health yang diprediksi akan dipublikasikan pada bulan tahun 2025 |
d-Entri Tambahan Nama Orang | |
337 Media Type | computer (rdamedia) |
526 Catatan Informasi Program Studi | Ilmu Kesehatan Masyarakat |
100 Entri Utama Nama Orang | Nurusysyarifah Aliyyah, author |
264a Kota Terbit | Depok |
300 Deskripsi Fisik | xxiv, 245 pages : illustration + appendix |
904a Pengisi Lembar Kerja | tanti-September2024 |
Akses Naskah Ringkas | |
856 Akses dan Lokasi Elektronik | |
502 Catatan Jenis Karya | Disertasi |
041 Kode Bahasa | ind |