001 Hak Akses (open/membership)membership
700 Entri Tambahan Nama OrangMohammad Syamsu Rosid, supervisor; Siti Fatimah, examiner
336 Content Typetext (rdacontent)
264b Nama PenerbitFakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia
710 Entri Tambahan Badan KorporasiUniversitas Indonesia. Fakultas Matematika dan Ilmu Pengetahuan Alam
049 No. Barkod21-25-59274700
504 Catatan Bibliografipages 78 - 79
852 LokasiPerpustakaan UI
338 Carrier Typeonline resource (rdacarrier)
590 Cat. Sumber Pengadaan KoleksiDeposit;
903 Stock Opname
534 Catatan Versi Asli1 - 79 pages
Tahun Buka Akses2022
053 No. Induk21-25-59274700
653 Kata KunciGeothermal; reduce to pole; MS-SVD; forward; Investment; alteration; Hydrothermal; Model; conceptual
040 Sumber PengataloganLibUI ind rda
245 Judul UtamaPenentuan Sistem Panas Bumi Lapangan C Kabupaten Sigi Berbasis Data Gravitasi dan Geomagnet = Determination of Geothermal System Field C in Sigi District Based on Gravity and Geomagnetic Data
264c Tahun Terbit2021
650 Subyek TopikModel; Hydrothermal alteration.; Alte?rations; Geothermal energy
850 Lembaga PemilikUniversitas Indonesia
520 Ringkasan/Abstrak/IntisariLapangan Panas bumi C memiliki sistem panas bumi non-vulkanik yang prospek. Lapangan yang berada di zona depresi ini dikontrol oleh aktivitas tektonik sesar Palu Koro. Sistem geotermal ini ditandai dengan kemunculan manifestasi mata air panas dengan temperatur bervariasi sekitar 37,8 ? 90,1?C dan tanah panas dengan suhu 100,6 ?C. Berdasarkan geotermometer Giggenbach, suhu reservoir ini diperkirakan sekitar 113-239 ?C sehingga termasuk sistem panas bumi temperatur rendah-sedang. Sebagai sistem panas bumi non-vulkanik, kondisi ini termasuk menarik untuk di eksplorasi. Investigasi lebih dalam pada area fokus diperlukan untuk mengidentifikasi keberadaan reservoir dan struktur pendukung sistem geothermal ini. Data gravitasi dilakukan dengan metode FHD (First Horizontal Derivative) dan SVD (Second Vertical Derivative) dalam menentukan keberadaan dan jenis patahan, serta MS-SVD (Multi Scale-Second Vertical Derivative) untuk mengetahui karakteristik patahan. Hasil analisis data gravitasi didapatkan 5 patahan oblique normal yang menunjukkan lapangan C dikontrol oleh struktur utama Sesar Palu Koro yang mengapit graben. Setelah itu dilakukan forward modelling 2D pada data gravitasi untuk mengetahui kondisi bawah permukaan. Data geomagnetik diproses dengan kontur anomali magnet total dan RTP (Reduce to Pole) untuk mendelineasi keberadaan zona alterasi hidrotermal sistem panas bumi di lapangan C. Keberadaan anomali rendah di dekat manifestasi utama mengindikasikan zona demagnetisasi oleh reservoar dan clay cap. Hasil Inversi magnetik mendukung dugaan reservoir dengan nilai suseptibilitas -0.00824 hingga -0.002 cgs pada elevasi 30 mdpl hingga kedalaman inversi 1803 m. Hasil forward modelling mengkonfimasi keberadaan reservoir pada batuan sekis yang kaya akan rekahan dengan densitas 2.65 g/cm³ dan clay cap berada pada filit yang memiliki densitas 2.7 g/cm3.. Keberadaan reservoir diikuti dengan indikasi heat source dari batuan granit yang berada di Timur dari manifestasi utama dengan densitas 2.58 g/cm3. Hasil analisis kedua metode di atas dan data pendukung menghasilkan model konseptual. ......Geothermal Field C has prospect non-volcanic geothermal system. The field which is in the depression zone is controlled by the tectonic activity of the Palu Koro fault. This geothermal system is characterized by the appearance of hot springs with a temperature of 37.8 ? 90.1?C and hot soil with a temperature of 100.6?C. based on the giggenbach geothermometer, the reservoir temperature is estimated to be around 113-239?C. As a non-volcanic geothermal system, this condition is interesting to explore. Further investigation of the focus area is needed to identify the presence of reservoirs and supporting structures for this geothermal system. Gravity and geomagnetic methods can identify geothermal structures and systems. Gravity data is carried out using the FHD (First Horizontal Derivative) and SVD (Second Vertical Derivative) methods in determining the presence and type of fault, and MS-SVD (Multi Scale-Second Vertical Derivative) in determining the characteristics of the fault. The results of the analysis of the gravity data showed 5 normal oblique faults in field C was controlled by the main structure of Palu Koro Fault which is flanking the graben. After that, 2D forward modelling was carried out on the gravity data to determine the subsurface conditions. Geomagnetic data was processed with total magnetic anomaly contour and RTP (Reduce to Pole) to delineate the presence of hydrothermal alteration zone of geothermal system in field C. The presence of low anomaly near the main manifestation of demagnetization indicates the presence of reservoir and clay cap. The results of the magnetic inversion support the reservoir assumption with a susceptibility value of -0.00824 to -0.002 cgs at an elevation of 30 masl to an inversion depth of 1803 m. Forward modeling results confirm the presence of a reservoir in schist rock which is rich in fractures with a density of 2.65 g/cm³ and clay cap is in phyllite which has a density of 2.7 g/cm³. main with a density of 2.58 g/cm³. The results of the analysis of the two methods above and the supporting data produce a conceptual model.
904b Pemeriksa Lembar Kerja
090 No. Panggil SetempatS-pdf
d-Entri Utama Nama OrangSaskia Nursarifa, author
500 Catatan UmumTidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris dan dipresentasikan sebagai makalah pada Seminar Internasional yaitu 7th ISCPMS
337 Media Typeunmediated (rdamedia)
d-Entri Tambahan Nama OrangM. Syamsu Rosid
526 Catatan Informasi Program StudiGeofisika
100 Entri Utama Nama OrangSaskia Nursarifa, author
264a Kota TerbitDepok
300 Deskripsi Fisikxiii, 77 pages : illustration
904a Pengisi Lembar KerjaDanang Yudi Mahasiswa-Juni 2025
Akses Naskah Ringkas
856 Akses dan Lokasi Elektronik
502 Catatan Jenis KaryaSkripsi
041 Kode Bahasaind