001 Hak Akses (open/membership) | membership |
700 Entri Tambahan Nama Orang | Endang Saefudin, supervisor; Ivandini Tribidasari Anggraningrum, supervisor; Yoki Yulizar, examiner; Jarnuzi Gunlazuardi, examiner; Rahmat Wibowo, examiner |
336 Content Type | text (rdacontent) |
264b Nama Penerbit | Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia |
710 Entri Tambahan Badan Korporasi | Universitas Indonesia. Fakultas Matematika dan Ilmu Pengetahuan Alam |
049 No. Barkod | 15-25-64570242 |
504 Catatan Bibliografi | pages 68-72 |
852 Lokasi | Perpustakaan UI |
338 Carrier Type | online resource (rdacarrier) |
590 Cat. Sumber Pengadaan Koleksi | Deposit;Deposit;Deposit;Deposit |
903 Stock Opname | |
534 Catatan Versi Asli | |
Tahun Buka Akses | 2021 |
053 No. Induk | 15-25-64570242 |
653 Kata Kunci | screen printed carbon electrode; gold electrode; sars cov-2; nacetyl neuraminic acid |
040 Sumber Pengatalogan | LibUI ind rda |
245 Judul Utama | Studi Elektrokimia dan Komputasi N-Acetyl Neuraminic Acid Sebagai Sensor Glikoprotein Sars Cov-2 dengan SPCE Termodifikasi Emas = Electrochemical and Computational Study of N-acetyl Neuraminic Acid as a Glycoprotein Sensor for SARS CoV-2 with Gold-modified SPCE |
264c Tahun Terbit | 2021 |
650 Subyek Topik | SARS-CoV-2 disease; Biosensors; Electrochemical sensors; Computational chemistry |
850 Lembaga Pemilik | Universitas Indonesia |
520 Ringkasan/Abstrak/Intisari | COVID-19 adalah penyakit yang disebabkan oleh Severe acute respiratory syndrom corona virus 2 (SARS CoV-2) yang menyerang sistem pernapasan manusia. Untuk menurunkan tingkat penyebaran virus yang tinggi, deteksi virus SARS CoV-2 yang cepat dan tepat sangat diperlukan. Pada penelitian ini pengembangan sensor deteksi SARS CoV-2 berbasis elektrokimia dengan agen pengenal N-acetyl neuraminic acid (Neu5Ac) telah dilakukan. Screen printed carbon electrode (SPCE) termodifikasi Au digunakan untuk mendeteksi keberadaan virus SARS CoV-2 melalui reaksi inhibisinya terhadap agen pengenal Neu5Ac. Neu5Ac membentuk interaksi yang stabil dengan S1 Glikoprotein pada pH7,6 suhu 300 K dengan nilai energi bebas gibss -6,4880 kkal/mol. Elektrodeposisi Au pada permukaan SPCE berhasil dilakukan dengan rata-rata ukuran Au terdeposisi sebesar 44-120 nm dan menutupi 23,2% permukaan elektroda karbon pada SPCE. Keberadaan Neu5Ac dalam larutan PBS pH7,6 dapat dideteksi dengan elektroda Au dan Au-SPCE dengan LOD masing-masing 27,27µM dan 35,7755 µM secara cyclic voltammetry. Pada konsentrasi Neu5Ac 160 µM, S1 Glikoprotein menunjukkan respon arus yang linier pada rentang konsentrasi 0 µg/ml sampai 0,01µg/ml selama waktu inhibisi 30menit dengan batas deteksi pada arus katoda (reduksi) : LOD = 0,0007 µg/ml LOQ = 0,0023 µg/ml dan pada arus Anoda (oksidasi) : LOD = 0,0014 µg/ml LOQ = 0,0045 µg/ml. Interferensi Hemaglutinin H1N1 tidak signifikan mempengaruhi sensor deteksi S1 glikoprotein.
......COVID-19 is a disease caused by Severe acute respiratory syndrome corona virus 2 (SARS CoV-2) which attacks the human respiratory system. To reduce the high rate of virus spread, a precise detection of the SARS CoV-2 virus is needed. In this study, the development of an electrochemical-based SARS CoV-2 detection sensor with the bioreceptor agent N-acetyl neuraminic acid (Neu5Ac) was carried out. Au-modified screen printed carbon electrode (SPCE) was used to detect the presence of the SARS CoV-2 virus through its inhibitory reaction against the bioreceptor agent Neu5Ac. Neu5Ac forms a stable interaction with S1 Glycoprotein at pH7.6 300 K with a gibss free energy value of -6.4880 kcal/mol. Au electrodeposition on the SPCE surface was successfully carried out with an average size of Au deposited at 44-120 nm and covered 23.2% of the carbon electrode surface on the SPCE. The presence of Neu5Ac in PBS solution pH7.6 can be detected with Au and Au-SPCE electrodes with LOD of 27.27µM and 35.7755 M by cyclic voltammetry, respectively. At a concentration of 160 M Neu5Ac, S1 Glycoprotein showed a linear current response in the concentration range of 0 g/ml to 0.01 g/ml during inhibition time of 30 minutes with a detection limit at the cathode current (reduction): LOD = 0.0007 g/ml LOQ = 0.0023 g/ml and at Anode current (oxidation): LOD = 0.0014 g/ml LOQ = 0.0045 g/ml. Hemagglutinin H1N1 interference did not significantly affect the S1 glycoprotein detection sensor. |
904b Pemeriksa Lembar Kerja | |
090 No. Panggil Setempat | T-pdf |
d-Entri Utama Nama Orang | |
500 Catatan Umum | Tidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris dan dipresentasikan sebagai makalah pada Seminar Internasional yaitu |
337 Media Type | computer (rdamedia) |
d-Entri Tambahan Nama Orang | |
526 Catatan Informasi Program Studi | Ilmu Kimia |
100 Entri Utama Nama Orang | Putri Hawa Syaifie, author |
264a Kota Terbit | Depok |
300 Deskripsi Fisik | xiv, 72 pages : illustration + appendix |
904a Pengisi Lembar Kerja | tanti-Agustus2025 |
Akses Naskah Ringkas | |
856 Akses dan Lokasi Elektronik | |
502 Catatan Jenis Karya | Tesis |
041 Kode Bahasa | ind |