001 Hak Akses (open/membership)membership
700 Entri Tambahan Nama OrangYuri Deswita, supervisor; Muhammad Sulaiman Kusumah Adiwirya, supervisor; Nada Ismah, examiner; Fadli Jazaldi, examiner
336 Content Typetext (rdacontent)
264b Nama PenerbitFakultas Kedokteran Gigi Universitas Indonesia
710 Entri Tambahan Badan KorporasiUniversitas Indonesia. Fakultas Kedokteran Gigi
504 Catatan Bibliografipages 66-70
049 No. Barkod14-25-96533182
852 LokasiPerpustakaan UI
338 Carrier Typeonline resource (rdacarrier)
590 Cat. Sumber Pengadaan KoleksiDeposit;Deposit
903 Stock Opname
534 Catatan Versi Asli
Tahun Buka Akses2025
053 No. Induk14-25-96533182
653 Kata Kuncisefalometri lateral; lateral cephalometry; kecerdasan buatan; artificial intelligence; OneCeph; WebCeph; tracing
040 Sumber PengataloganLibUI ind rda
245 Judul UtamaPerbedaan Hasil Pengukuran Parameter Sefalometri Lateral Berbasis Digital Antara Metode Manual dengan Kecerdasan Buatan = Differences in Digital-based Lateral Cephalometry Parameter Measurement Results Between Manual Method and Artificial Intelligence
264c Tahun Terbit2025
650 Subyek TopikArtificial Intelligence; Cephalometric parameters
850 Lembaga PemilikUniversitas Indonesia
520 Ringkasan/Abstrak/IntisariLatar Belakang: Pengukuran parameter Sefalometri Lateral yang menjadi bagian integral dalam penegakkan diagnosis yang selama ini dilakukan secara konvensional dengan kertas asetat dan alat tulis sebagai baku emas (gold standard), perlahan mulai digantikan dengan metode manual berbasis digital maupun dengan kecerdasan buatan yang menawarkan efisiensi dan mobilitas yang lebih baik. OneCeph? dan WebCeph? merupakan contoh aplikasi dan penyedia layanan tersebut. OneCeph? merupakan aplikasi smartphone yang telah teruji akurasi dan reliabilitasnya dalam pengukuran parameter Sefalometri Lateral, sedangkan WebCeph? merupakan aplikasi sekaligus web yang menyediakan layanan pengukuran dengan kecerdasan buatan. Hingga saat ini, belum banyak penelitian yang membandingkan secara langsung kedua metode pengukuran parameter Sefalometri Lateral yang berbeda tersebut dengan menjadikan salah satunya yang telah teruji keakuratan dan reliabilitasnya sebagai kebenaran dasar (ground truth) serta dengan menambahkan metode pengukuran berbasis kecerdasan buatan dengan koreksi manual. Tujuan: Menganalisis perbedaan hasil pengukuran parameter Sefalometri Lateral berbasis digital antara metode manual dengan kecerdasan buatan, serta kecerdasan buatan dengan koreksi manual. Metode: Sebanyak 90 Sefalogram Lateral yang memenuhi kriteria inklusi dan eksklusi sebagai sampel dilakukan pengukuran terhadap 13 parameter menggunakan kedua aplikasi dengan ketiga metode berbasis digital, yaitu metode manual, metode kecerdasan buatan, dan metode kecerdasan buatan dengan koreksi manual. Uji intraobserver dan interobserver dilakukan dengan uji Intraclass Correlation Coefficient (ICC), perbedaan hasil pengukuran antar metode dianalisis dengan uji One-Way ANOVA dan Kruskal-Wallis. Hasil: 3 dari 13 variabel yang menunjukkan perbedaan bermakna (p<0,05) pada kelompok metode kecerdasan buatan terhadap dua kelompok lain, yaitu SNA, ANB, dan U1NA (Linear). Kesimpulan: Meskipun terdapat perbedaan bermakna hasil pengukuran parameter Sefalometri Lateral antara metode kecerdasan buatan dengan dua metode lain pada beberapa variabel, tetapi potensi serta efisiensi yang ditawarkan metode berbasis kecerdasan buatan cukup baik ketika dibandingkan dengan metode manual. ...... Background: The measuring Lateral Cephalometric parameters, which is an integral part of establishing a diagnosis, which has previously been carried out conventionally with acetate paper and writing instruments as the gold standard, is slowly starting to be replaced by digital-based manual methods and artificial intelligence which offer better efficiency and mobility. OneCeph? and WebCeph? are examples of such applications and service providers. OneCeph? is a smartphone application that has been tested for accuracy and reliability in measuring Lateral Cephalometric parameters, while WebCeph? is an application and web that provides measurement services with artificial intelligence. Objective: To analyze the differences in digital-based Lateral Cephalometric parameter measurement results between manual methods with artificial intelligence, and artificial intelligence with manual correction. Methods: A total of 90 lateral cephalograms that met the inclusion and exclusion criteria as samples were measured for 13 parameters using both applications with three digital-based methods, namely manual methods, artificial intelligence methods, and artificial intelligence methods with manual correction. Intraobserver and interobserver tests were carried out using the Intraclass Correlation Coefficient (ICC) test, differences in measurement results between methods were analyzed using the One-Way ANOVA and Kruskal-Wallis tests. Results: 3 of the 13 variables showed significant differences (p<0.05) in the artificial intelligence method group against the other two groups, namely SNA, ANB, and U1NA (Linear). Conclusion: Even though there are significant differences in the results of measuring Lateral Cephalometry parameters between the artificial intelligence method and the other two methods on several variables, the potential and efficiency offered by the artificial intelligence-based method is quite good when compared with the manual method.
904b Pemeriksa Lembar Kerja
090 No. Panggil SetempatS-pdf
d-Entri Utama Nama Orang
500 Catatan UmumTidak dapat diakses di UIANA, karena: akan ditulis dalam bahasa Inggris untuk dipersiapkan terbit pada Jurnal Internasional yaitu Journal of Orofacial Orthopedics yang diprediksi akan dipublikasikan pada bulan Desember tahun 2025
337 Media Typecomputer (rdamedia)
d-Entri Tambahan Nama Orang
526 Catatan Informasi Program StudiPendidikan Dokter Gigi
100 Entri Utama Nama OrangMuhammad Siraj Syandi, author
264a Kota TerbitJakarta
300 Deskripsi Fisikxvi, 70 pages + appendix
904a Pengisi Lembar KerjaSugiarti-Juli-2025
Akses Naskah Ringkas
856 Akses dan Lokasi Elektronik
502 Catatan Jenis KaryaSkripsi
041 Kode Bahasaind