Evaluasi sistem pemantauan korosi pada fasilitas proses produksi minyak dan gas lepas pantai = Corrosion monitoring in offshore oil and gas process production facility

Bara Mahendra Sukaton; Andi Rustandi, supervisor (Fakultas Teknik Universitas Indonesia, 2008)

 Abstrak

Proses produksi minyak dan gas lepas pantai meliputi bejana, dan sistem pipa yang rentan terhadap serangan korosi. Untuk meminimalkan kegagalan yang terjadi akibat serangan korosi dan mencegah shutdown yang tidak direncanakan dipakailah sistem pemantauan korosi. Sistem pemantauan korosi disini diterapkan terbatas yaitu hanya pada bagian fasilitas proses produksi. Bagian tersebut antara lain meliputi production separator, atmospheric separator, scrubber, compressor, dan cooler. Pada system pemantauan korosi yang diterapkan sebelumnya corrosion coupon dan probe ditempatkan sangat terbatas. Evaluasi sistem pemantauan korosi dilakukan berdasarkan NORSOK M CR 505 dan NACE RP 077599. Sistem pemantauan korosi yang baru ditempatkan pada jalur pipa yang korosif seperti pada jalur masuk fluida 3 fasa, jalur keluar air, jalur keluar gas pada separator, jalur keluar minyak pada separator, dan jalur keluar gas pada cooler. Metode yang dipakai dalam pemantauan korosi ini adalah weight loss coupon, electrical resistance, linear polarization resistance, dan weld probe. Selain itu pembahasan disini juga berisikan arah penempatan alat pemantau korosi terhadap pipa untuk mendapatkan data korosi yang benar-benar sesuai dengan keadaan di lapangan.

Oil and gas production facility comprise of vessels and piping system that prone off corrosion attack. To minimize the failure caused by corrosion attack and to prevent unplanned shutdown the corrosion monitoring system is applied. Corrosion monitoring system discussed in this paper limit only on process production facility. Process production facility consists of production separator, atmospheric separator, gas scrubber, compressor, and cooler. On previous corrosion monitoring system, corrosion probe and coupon were very limited. The evaluation this corrosion monitoring based on NORSOK M CR 505 and NACE RP 077599. Recommendations for new corrosion monitoring system are corrosion monitoring device were applied in the corrosive line, such as, the inlet of 3 phase fluids, water outlet, gas outlet of separator, oil outlet of separator, and gas outlet after cooler. This corrosion monitoring system applies three different methods, which are, weight loss coupon, electrical resistance, linear polarization resistance, and weld probe. In this paper discussion made also covers corrosion monitoring device position in pipe to obtain most representative data about corrosion occurred.

 Metadata

Jenis Koleksi : UI - Skripsi Open
No. Panggil : S41672
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2008
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 61 pages : illustration ; 28 cm + appendix