Koefisien perpindahan panas pada pipa bulat

Rino Ardianto; Yanuar, supervisor; Talahatu, Marcus Alberth, examiner; Hadi Tresno Wibowo, examiner; Mukti Wibowo, examiner; Sunaryo, examiner (Fakultas Teknik Universitas Indonesia, 2012)

 Abstrak

ABSTRAK
Penanganan beban termal pada dunia industri sangat diperlukan. Sistem alat penukar kalor bisa dikembangkan pada sisi fluida yang digunakan dan desain pipa yang digunakan. Respon dalam bidang thermal adalah maraknya kembali perhatian akan pentingnya alat penukar kalor (heat exchanger). Sebuah alat penukar kalor yang baik
harus ditunjang oleh koefesien perpindahan panas yang baik. Koefesien perpindahan panas sendiri di pengaruhi oleh bilangan Reynolds. Dalam penelitian ini, dilakukan rancang bangun sebuah alat penukar kalor tipe double pipe dengan variasi pada pipa air panas, dimana pada pipa luar adalah pipa baja karbon memiliki koefisien perpindahan kalor konduksi 54 W/m.K dan memiliki dimensi panjang pipa 1 m, diameter luar (Ø out) 88.6 mm, dan diameter dalam (Ø in) 85 mm dan pipa dalam adalah pipa baja karbon memiliki koefisien perpindahan kalor konduksi 54 W/m.K dan memiliki dimensi panjang
pipa 1.2 m, diameter luar (Ø out) 30 mm, dan diameter dalam (Ø in) 28 mm. Bedasarkan pengujian didapatkan grafik kenaikan nilai koefisien perpindahan kalor sebanding dengan kenaikan bilangan Reynolds. Profil kotak memiliki nilai koefisien perpindahan panas
yang lebih tinggi jika dibandingkan dengan profil bulat. Pada perbedaan jenis aliran Psangat berpengaruh terhadap nilai koefisien perpindahan panas profil bulat, sedangkan pada profil kotak tidak begitu terlihat perbedaannya.

ABSTRACT
Handling of thermal load on the industrial world is indispensable. Heat exchanger system can be developed on the side of the fluid used and the design of pipe used. Response in the thermal field is widespread concern about the importance of re-heat exchanger (heat exchanger). A good heat exchanger must be supported by a good heat transfer coefficient. Heat transfer coefficient itself is influenced by the Reynolds number. In this study, carried out design and construction of an appliance type double pipe heat exchanger with a variation on the hot water pipes, where the outer pipe is carbon steel pipe has a conduction heat transfer coefficient of 54 W / mK and has dimensions of 1 m length of pipe, outer diameter (Ø out) 88.6 mm, and diameter in (Ø in) 85 mm and pipe in carbon
steel pipe is a conduction heat transfer coefficient of 54 W / mK and has dimensions of 1.2 m length of pipe, outer diameter (Ø out) 30 mm, and diameter in (Ø in) 28 mm. Based on the obtained testing the graph increases the heat transfer coefficient is proportional to the increase in Reynolds number. Profiles box has a heat transfer coefficient values are higher if compared to the rounded profile. In different types of flow greatly affect the heat transfer coefficient value rounded profile, whereas the profile square is not so pronounced.

 File Digital: 1

 Metadata

Jenis Koleksi : UI - Skripsi Open
No. Panggil : S1413
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2012
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xiv, 39 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S1413 14-24-41095740 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20293309
Cover