The heat and energy transfer around a cluster of traditional Balinese buildings is extremely
complicated and difficult to determine by modeling an isolated building (eg. via symmetry conditions).
Full scale models of traditional buildings have been investigated by using numerical method based on the
finite element method to assess the facts of roof type on heat and energy transfer. A standard k-e model
is adopted with low values of k and e combined with multi-blocks grids, in order to reduce the over-
estimation of the production term of the turbulent kinetic energy in standard k-s turbulence models.