ABSTRAK
Skripsi ini bertujuan untuk mengetahui pengaruh temperatur beton massa pada kedalaman 4 meter. Pengaruh temperatur yang diamati adalah temperatur puncak, perbedaan temperatur, dan tegangan. Pada umumnya, syarat batas temperatur puncak adalah 70 oC dan perbedaan temperatur ≥ 20 oC. Kondisi tersebut diterapkan untuk kondisi kelembapan dan temperatur di Eropa. Perbedaan temperatur yang terjadi tergantung dari pengendalian temperatur yang dilakukan. Temperatur puncak yang terjadi ± 77.75 oC. Temperatur puncak yang terjadi tergantung dari initial temperature dan mix design. Tegangan yang terjadi dipengaruhi oleh perubahan temperatur pada nodal. Perubahan temperatur yang ekstrim dapat menimbulkan teganan tarik yang melebihi kuat tarik raft foundation. Oleh karena itu diperlukan pengendalian temperatur permukan dan bagian yang terkena udara. Pengendalian dapat dilakukan dengan lapisan insulasi.

Abstract
This final report aims to investigate the effect of 4 meter thickness mass concrete temperature. The observed temperature influence is peak temperature, temperature difference, and stress. In general, the peak temperature boundary condition is 70 oC and temperature difference is higher than 20 oC. These situations apply to the conditions of humidity and temperature in Europe. Temperature difference that occurs depends on the temperature control that is done. Peak temperature occurs in average 77.75 oC. Peak temperature depends on the initial temperature and mix design of concrete. Stress that occurs is influenced by the changes in the nodal temperatures. Extreme temperature changes can cause maximum tension that exceeds the tensile strength of the raft foundation. Therefore, there is the need to control the surface temperature and the air exposed side. Temperature control can be done with a layer of insulation.

 File Digital: 1

 Metadata

Jenis Koleksi : UI - Skripsi Open
No. Panggil : S43584
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2012
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xiii, 99 pages ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S43584 14-17-665264073 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20312737
Cover