Pengaruh laju alir umpan dan jumlah serat membran pada penyisihan amonia dari air limbah menggunakan proses gabungan membran, reaktor hibrida ozon-plasma dan ozonator = Effect of feed flow rate and number of fiber on ammonia removal from waste water through combination of membrane, ozone-plasma hybrid reactor and ozonato

Yuniar Nuraeni; Sutrasno Kartohardjono, supervisor; Eva Fathul Karamah, examiner; Doni Adinata, examiner; Setiadi, examiner (Fakultas Teknik Universitas Indonesia, 2012)

 Abstrak

ABSTRAK
Penelitian ini bertujuan untuk menganalisis efektivitas gabungan proses kontaktor
membran serat berongga dengan reaktor hibrida ozon-plasma (RHOP) dan
ozonator pada penyisihan amonia yang terlarut dalam air limbah melalui uji
perpindahan massa dan uji hidrodinamika. Variabel proses yang divariasikan pada
proses penyisihan amonia menggunakan membran adalah jumlah serat membran
40, 50, dan 60 serta laju alir air umpan pada 3, 4, dan 5 Lpm. Khusus untuk proses
penyisihan amonia menggunakan gabungan proses kontaktor membran serat
berongga dengan RHOP dan ozonator laju alir umpan diatur pada 0,78 Lpm.
Reaktor hibrida ozon-plasma & ozonator dapat membantu mengurangi beban
penyisihan pada membran dengan cara mendegradasi amonia. Degradasi amonia
tersebut terjadi karena adanya radikal OH?. Selain itu, terbentuknya ion OH- yang
dapat menggeser kesetimbangan reaksi amonia dalam air ke arah pembentukan
gas amonia sehingga meningkatkan jumlah amonia yang akan disisihkan oleh
kontaktor membran. Efisiensi penyisihan maksimum sebesar 52% diperoleh pada
penyisihan amonia menggunakan proses gabungan membran dengan RHOP &
ozonator kondisi variasi jumlah serat membran 60 dan laju alir 0,78 Lpm.

ABSTRACT
This study aims to analyze the effectiveness of the combined process of hollow
fiber membrane contactor with ozone-plasma hybrid reactor (RHOP) and the
ozonator on the removal of dissolved ammonia in the waste water through the test
of mass transfer and hydrodynamic. Varied process variables on the ammonia
removal process through a membrane are the amount of fiber membrane 40, 50,
and 60 and the feed flow rate at 3, 4, and 5 Lpm. Especially for ammonia removal
process through a combination of the hollow fiber membrane contactor with
RHOP and ozonator, feed flow rate set at 0.78 Lpm. Ozone-plasma hybrid reactor
& ozonator reduce the load on the membrane by way of allowance degrade
ammonia. Degradation of ammonia is due to OH? radicals. In addition, the
formation of OH- that can lead the equilibrium reaction of ammonia in water to
the formation of ammonia gas thus increase the amount of ammonia that will be
set aside by membrane contactor. The maximum efficiency of ammonia removal
achieved 52% through combination of hollow fiber membrane, RHOP, and
ozonator with 60 fibers and 0,78 Lpm feed flow rate.
Key words.

 File Digital: 1

 Metadata

Jenis Koleksi : UI - Skripsi Open
No. Panggil : S43819
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2012
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xiii, 77 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S43819 14-24-89045779 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20314097
Cover