Identifikasi Karakteristik Limbah Padat Rumah Sakit Kepolisian Pusat Raden Said Sukanto serta Rekomendasi Sistem Pengelolaannya = Identification of Solid Waste Characteristics and Recommendation for Waste Management System in Raden Said Sukanto Central Police Hospital

Astri Maharani; El Khobar Muhaemin Nazech, supervisor; Firdaus Ali, supervisor; Djoko M. Hartono, examiner; Gabriel Soedarmini Boedi Andari, examiner (Fakultas Teknik Universitas Indonesia, 2013)

 Abstrak

Rumah sakit adalah gedung tempat menyediakan dan memberikan pelayanan kesehatan yang meliputi berbagai masalah kesehatan. Aktivitas rumah sakit akan menghasilkan sejumlah hasil samping berupa limbah, baik limbah padat, cair, dan gas yang mengandung kuman patogen, zat-zat kimia serta alat-alat kesehatan yan pada umumnya bersifat berbahaya dan beracun. Untuk meningkatkan mutu pelayanan perlu pula ditingkatkan sarana untuk mengatasi limbah tersebut. Untuk itu diperlukan pengetahuan mengenai karakteristik dari limbah padat di Rumah Sakit Kepolisian Pusat Raden Said Sukanto, dalam hal ini timbulan dan komposisinya, sehingga dapat diberikan rekomendasi sistem pengelolaan limbah padat yang sesuai dengan peraturan yang berlaku.
Rumah Sakit Kepolisian Pusat Raden Said Sukanto sudah memilikki sistem pengelolaan limbah padat namun dalam pelaksanaannya masih kurang baik. Hasil sampling menunjukkan limbah padat non medis yang dihasilkan adalah 1,37 kg/tempat tidur/hari. Sedangkan untuk limbah padat medis tajam sebesar 2,75 kg/ hari dan limbah padat medis non tajam sebesar 41,48 kg/hari. Analisa dari hasil sampling dan kuesioner menunjukkan bahwa masih banyak aspek yang perlu diperbaiki. Potensi reduksi sampah di rumah sakit ini ternyata sebesar 49,39% sehingga jumlah residu sampah yang akan dibuang sebesar 83,69 kg/hari.

Hospital is an institution which provide healthcare and treatment for various health problems. Medical waste from healthcare activity; range from waste water, gas emission, and solid waste; contain pathogenic germ, chemical substances, and medical equipments which were considered hazardous and toxic. Waste treatment facility improvement is needed to increase the quality of the hospital general service. A study concerning the characteristics of solid waste, in this case the generation rate and composition, produced from Raden Said Sukanto Central Police Hospital is necessary to planned an appropriate solid waste management in accordance to existing regulations.
There is an existing solid waste management in Raden Said Sukanto Central Police Hospital, however the execution is lacking and in need of refinements. In RS sukanto the non-medical waste generation rate is 1,37 kg/bed/day. Whereas the medical waste generated divided into two categories, the sharp waste generation rate is 2,75 kg/bed/day and the non-sharp medical waste is 41,48 kg/bed/day. Analysis of the sampling result and questionnaires yields a conclusion that there several aspects in need of improvements. Waste reduction in this particular hospital could potentially reached 49,39% or disposal of residual waste as much as 83,69 kg/day.

 File Digital: 1

Shelf
 S45983-Astri Maharani.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S45983
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2013
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated
Tipe Carrier : volume
Deskripsi Fisik : xvii, 87 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S45983 14-23-44942363 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20347330
Cover