Analisis tegangan lebih peralihan pada pensaklaran komputer dan beban RLC = Analysis of transient overvoltage of computer and RLC load switching

Sinaga, Felix Larry F.; I Made Ardita Y., examiner; Faiz Husnayain, examiner; Iwa Garniwa M.K., supervisor (Fakultas Teknik Universitas Indonesia, 2014)

 Abstrak

Fenomena tegangan lebih peralihan merupakan salah satu permasalahan kualitas daya sistem tenaga listrik karena akan terjadi kenaikan tegangan dengan waktu yang sangat cepat yang menggangu sistem. Tegangan lebih peralihan pada sistem tenaga listrik secara garis besar bersumber dari surja hubung dan surja petir. Surja hubung ini terjadi pada saat pensaklaran beban listrik, sedangkan surja petir berasal dari adanya sambaran petir pada rangkaian listrik. Surja hubung merupakan sumber tegangan lebih peralihan yang paling sering terjadi pada peralatan listrik karena hampir semua peralatan listrik mempunyai saklar untuk menyambung dan memutus beban tersebut dengan sumber listrik. Pada saat terjadi pensaklaran pada suatu rangkaian listrik yang memiliki komponen kapasitor akan terjadi pengisian dan pelepasan energi secara cepat yang menimbulkan perubahan paramater listrik berupa arus dan tegangan yang sangat cepat pada sistem. Komputer merupakan salah satu beban peralatan listrik yang dapat menimbulkan tegangan lebih ketika dilakukan penutupan saklar. Pada komputer terdapat komponen resistor, induktor dan kapasitor yang mempengaruhi bentuk dan besarnya tegangan lebih peralihan yang terjadi. Tegangan lebih peralihan ini juga dilakukan pemodelannya pada beban RLC murni untuk melihat tegangan lebih yang terjadi saat dilakukan pensaklaran terhadap variasi beban resistor, induktor dan kapasitor. Dengan adanya simulasi ini akan digunakan untuk membandingkan tegangan lebih yang terjadi dengan tegangan lebih pada beban komputer.

Fenomena of transient over voltage is one of power system quality problem because the level of voltage will increase with very fast time that it will bother the system. Transient over voltage in power system sourced from switching surge and lighting surge. Switching surge occured when switching load, meanwhile lighting surge sourced from clap on electric circuit.Switching surge is the most of sourced transient over voltage on electrical equipment because most of them have switch for connected and cut off load from sourced. When swtiching occur on an electric circuit that has capacitor will happen charging and discharging energy fast which create electric paramater transformation very fast such as current and voltage on system. Computer is one of electrical equipment which create over voltage while closing the switch. On a computer, there is resistor component, induktor, and capacitor that affect form and level of transient over voltage that occur. This transient over voltage is modeled with simulation on RLC load to see the over voltage that occured when switching on varity of resistor load, induktor and capacitor. This simulation will be used to compare the over voltage which occured with the over voltage on computer.

 File Digital: 1

Shelf
 S55253-Felix Larry F. Sinaga.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S55253
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2014
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 65 pages : illustration ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S55253 14-18-755588609 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20386596
Cover