Pengukuran bioimpedance untuk plethysmography dengan menggunakan AD5933 = Bioimpedance measurement for plethymography by using AD5933

Ahmad Arisa Ardiawan; Sastra Kusuma Wijaya, supervisor; Lingga Hermanto; Arief Syarifuddin Fitrianto, examiner ([Publisher not identified] , 2014)

 Abstrak

[ABSTRAK
Pengukuran bio-impedansi merupakan salah satu metode untuk diagnosis berdasarkan nilai impedansi sebagai fungsi dari frekuensi. Bio-impedansi memanfaatkan karakteristik hambatan dari makhluk hidup dalam menghambat arus yang lewat. Dengan melihat perubahan arus ini maka pengukuran bioimpedansi dapat dilakukan. Pengukuran volume sebuah jaringan atau plethysmography biasanya dilakukan untuk volume gas pada paru-paru. Plethysmography dapat mengamati paru-paru pada saat inspirasi dan ekspirasi yang menunjukkan perbedaan volume. Untuk mendapatkan perbedaan itu, metode pengukuran thoracic atau bagian dada untuk plethysmography sering digunakan. Dengan mengkombinasikan metode thoracic dan Impedance Converter AD5933, pengukuran bio-impedansi untuk plethysmography dapat dilakukan. AD5933 diprogram dengan pengaturan sweep frequency yang dapat mengukur besar impedansi, bilangan real, bilangan imaginer dan fasa. Selanjutnya, pengukuran bio-impedansi untuk plethysmography ini dilakukan dengan mengolah data dari AD5933 terhadap waktu dan menghasilkan sinyal yang merepresentasikan sinyal dari paru-paru dan diperoleh sinyal plethysmography dari tiga subjek volunteer (pria berumur 20-23 tahun) dengan berat yang sama yang dibedakan dari perokok atau tidak perokok dan olahraga.

ABSTRACT
, Bio-impedance measurement is one method for diagnosis based on the value of
the impedance as a function of frequency. Utilizing bio-impedance characteristics
of living things in the barriers inhibiting the flow through. By looking at the
change in the flow of bio-impedance measurement can be performed.
Measurement of the volume of a tissue or plethysmography is usually done for the
volume of gas in the lungs. Plethysmography can observe the lungs during
inspiration and expiration which shows the difference in volume. To get the
difference, the method of measurement for thoracic or chest plethysmography is
often used. By combining methods and thoracic impedance Converter AD5933,
measurement of bio-impedance plethysmography to do. AD5933 is programmed
with settings that can measure the frequency sweep large impedance, real
numbers, imaginary numbers and phase. Furthermore, measurement of bioimpedance
plethysmography for this by processing data from AD5933 to time and
produce signals that represent the signal from the lungs and plethysmography
signals obtained from three volunteer subjects (men aged 20-23 years) with same
weight were distinguished from smokers or not smokers and sport routine.]

 File Digital: 1

Shelf
 S56185-Ahmad Arisa Ardiawan.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S56185
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2014
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xv, 104 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S56185 14-18-600026513 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20387596
Cover