Aplikasi teknologi ozonasi katalitik menggunakan zeolit alam lampung zal dalam pengolahan limbah cair Rumah Sakit studi kasus Rumah Sakit Bumi Waras Bandar Lampung = The application of catalytic ozonation technology using zal zeolit alam lampung for hospital wastewater treatment case Bumi Waras Hospital Bandar Lampung

Nandha Riveri Sesunan; Setijo Bismo, supervisor; Sutrasno Kartohardjono, examiner; Eva Fathul Karamah, promotor; Yuswan Muharam, examiner (Fakultas Teknik Universitas Indonesia, 2014)

 Abstrak

ABSTRACT
Penelitian ini menawarkan alternatif metode dalam penyisihan kandungan
pencemar pada limbah cair rumah sakit dengan teknologi ozonasi katalitik
menggunakan Zeolit Alam Lampung (ZAL) jenis klinoptilolit yang dikombinasikan
dengan radiasi sinar UV. Penelitian ini dilakukan dengan memvariasikan waktu
penyisihan (0, 15, 30, 60, dan 120 menit); dan sistem konfigurasi ozonasi dalam
pengolahan limbah cair, yaitu: ozon tunggal, Ozon-UV, Ozon-ZAL, Ozon-UV-ZAL.
Analisis yang dilakukan meliputi analisis COD dengan metode FAS, analisis NH3-N
dengan metode Nessler, metode TPC untuk mengetahui jumlah Coliform, dan analisis
antibiotik dengan menggunakan metode aminoantipirin. Hasil penelitian
menunjukkan bahwa konfigurasi Ozon-UV-ZAL sebagai konfigurasi yang terbaik
dari semua konfigurasi yang dirancang dengan efisiensi penurunan COD, NH3-N,
E.coli, Coliform, dan antibiotik masing-masing sebesar 50%; 28,74%; 100%;
83,14%; dan 100%.

ABSTRACT
This research attempts to proffer an alternative method to eliminate pollutants
from hospital wastewater through catalytic ozonation technology using combination
of ZAL and UV radiation. The research was conducted with various circulation of
time (0, 15, 30, 60, and 120 minutes); and system configuration of ozonation in
wastewater treatment (Ozone, Ozone-UV, Ozone-ZAL, and Ozone-UV-ZAL). The
results were analyzed which comprising of COD by FAS method, NH3-N by Nessler
Method, TPC method to determine the number of E.coli/coliform, and
aminoantipyrine method to antibiotics (phenol derivatives). To sum up, this research
pointed out that the configuration of Ozone-UV-ZAL became the best configuration
to treat the hospital wastewater with efficiency of removal reached: 50%; 28.74%;
100%-83.14%; and 100%.

 File Digital: 1

Shelf
 T41835-Nandha Riveri Sesunan.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T41835
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2014
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 62 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T41835 15-17-357808986 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20388760
Cover