UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Faktor-faktor yang berhubungan dengan in-stent restenosis pada pasien pasca intervensi koroner perkutan = Factors related to in-stent restenosis in patients after percutaneous coronary intervention

(Fakultas Kedokteran Universitas Indonesia, 2014)

 Abstrak

[Latar Belakang. Angka kejadian In-Stent Restenosis (ISR) pasca Intervensi
Koroner Perkutan (IKP) baik pada penggunaan Bare-Metal Stent (BMS) maupun
Drug-Eluting Stent (DES) masih tinggi. Tujuan. Mengetahui faktor-faktor yang
berhubungan dengan ISR pada pasien pasca IKP. Metode. Desain penelitian
potong lintang retrospektif ini dilakukan dengan menggunakan rekam medik
pasien pasca IKP yang menjalani follow-up angiografi di Pelayanan Jantung
Terpadu/Rumah Sakit Umum Pusat Negeri Dr. Cipto Mangunkusumo dalam
kurun waktu bulan Januari 2009 sd. Maret 2014. Gambaran angiografi ISR bila
diameter stenosis pada follow-up angiografi lebih dan sama dengan 50 persen baik
di dalam stent maupun menjulur keluar lima mm baik dari ujung proksimal
maupun distal stent. Analisis multivariat pada penelitian ini dilakukan dengan
menggunakan regresi logistik ganda. Hasil. 289 subyek penelitian terdiri dari 133
pasien dengan ISR dan 156 pasien tanpa ISR. Angka kejadian ISR pada
penggunaan BMS dan DES masing-masing sebesar 61,3% dan 40,7%. Jenis stent
(OR=4,83; 95% IK 2,51-9,30; p=0,001), panjang stent (OR=3,71; 95% IK 1,99-
6,90; p=0,001), lesi di bifurkasi (OR=2,43; 95% IK 1,16-5,10; p=0,019), merokok
(OR=2,30; 95% IK 1,33-3,99; p=0,003), diameter pembuluh darah (OR=2,18;
95% IK 1,2-3,73; p=0,005), hipertensi (OR=2,16; 95% IK 1,16-4,04; p=0,016)
dan Diabetes Melitus/DM (OR=2,14; 95% IK; p=0,007) sebagai faktor prediksi
ISR. Kesimpulan. Jenis stent, panjang stent, lesi di bifurkasi, merokok, diameter
pembuluh darah, hipertensi dan DM merupakan faktor-faktor yang berhubungan
dengan ISR pada pasien pasca IKP., Background. The incidence of In-Stent Restenosis (ISR) after Percutaneous
Coronary Intervention (PCI) both in the use of Bare-Metal Stent (BMS) and Drug-
Eluting Stents (DES) are still high. Purpose. To determine factors related to ISR
in patients after PCI. Method. A retrospektif cross-sectional study was conducted
using medical records of patients after PCI who underwent follow-up of
angiography in in the period between January 2009 to March 2014 in The
Integrated Cardiac Service/Public Hospital Center Dr. Cipto Mangunkusumo
Jakarta. Angiographic ISR was defined as diameter stenosis ≥ 50% at follow-up
angiography in the within of the stent, and within its five mm proximal and distal
edges. Multivariate analysis performed in this study using regression multiple
logistic. Results. 289 study subjects consisted of 133 patients with and 156
patients without ISR. The incidence of ISR in the use of BMS and DES,
respectively 61,3% and 40,7%. Using multivariate analysis, type of stent
(OR=4,83; 95% CI 2,51-9,30; p=0,001), stent length (OR=3,71; 95% CI 1,99-
6,90; p=0,001), bifurcation lesions (OR=2,43; 95% CI 1,16-5,10; p=0,019),
smoking (OR=2,30; 95% CI 1,33-3,99; p=0,003), blood vessel diameter
(OR=2,18; 95% CI 1,2-3,73; p=0,005), hypertension (OR=2,16; 95% CI 1,16-
4,04; p=0,016) and Diabetes Mellitus/DM (OR=2,14; 95% CI; p=0,007) were
identified as predictors of ISR. Conclusion. Type of stent, stent length,
bifurcation lesions, smoking, blood vessel diameter, hypertension and DM were
factors related to ISR in patients after PCI.]

 File Digital: 1

Shelf
 SP-Dedi Wihanda.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-Pdf
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: Fakultas Kedokteran Universitas Indonesia, 2014
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xvi, 73 hlm. : ill. ; 28 cm. + lamp.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-Pdf TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20391325
Cover