Evaluasi penerapan keselamatan kebakaran gedung menggunakan computeried fire safety evaluation system cfses di fakultas ilmu sosial dan ilmu politik universitas indonesia tahun 2014 = Evaluation of building fire safety application using computerized fire safety evaluation system cfses at faculty of social and politics universitas indonesia on 2014/ Ahmad Noor Yuhdi

Ahmad Noor Yuhdi; Fatma Lestari, supervisor; Titi Muswati Putranti, examiner; Pangaribuan, Adrianus ([Publisher not identified] , 2015)

 Abstrak

[Skripsi ini membahas evaluasi penerapan keselamatan kebakaran gedung
mengunakan perangkat lunak Computerized Fire Safety Evaluation System
(CFSES) di Fakultas Ilmu Sosial dan Ilmu Politik Universitas Indonesia yang
terletak di Kampus UI Depok. Skripsi ini menggunakan desain penelitian deskriptif
dengan pendekatan semi kuantitatif dan bertujuan untuk mengetahui penerapan
keselamatan kebakaran gedung. Evaluasi dilakukan berdasarkan kesesuaian 12
safety parameter dan persyaratan tambahan pada NFPA 101A: Alternative
Approaches to Life Safety dan standar NFPA 101: Life Safety Code. Penelitian
dilakukan pada gedung A, B, D, dan H Fakultas Ilmu Sosial dan Ilmu Politik
Universitas Indonesia. Hasil penelitian menunjukkan bahwa gedung B, D, dan H
belum memenuhi persyaratan keselamatan minimum pada NFPA 101 Life Safety
Code, This study discusses the evaluation of building fire safety application using
Computerized Fire Safety Evaluation System (CFSES) software at Faculty of
Social and Politics Universitas Indonesia on 2014. This study uses descriptive study
design with semi-quantitative approach and has purpose to evaluate the building
fire safety application. The evaluation is based on suitability 12 safety parametes
and additional requirements in NFPA 101A: Alternate Approaches to Life Safety
and NFPA 101: Life Safety Code Standards. This study is consist of A, B, D, and
H building at Faculty of Social and Politics Universitas Indonesia. The results
showed that the building fire safety application at B, D, and H buildings not meet
the minimum safety requirements in NFPA 101: Life Safety Code.]

 File Digital: 1

Shelf
 S58452-ahmad noor yuhdi .pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S58452
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2015
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xxii, 208 hlm. : ill. ; 29 cm. + lamp.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S58452 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20402451
Cover