Studi pendahuluan deteksi adenosin fosfat berbasis sel elektroforesis kapiler = Preliminary studies of adenosine phosphate detection cell based capillary electrophoresis / Muhammad Maghribul Falah

(Universitas Indonesia, 2015)

 Abstrak

[Elektroforesis kapiler merupakan suatu metode pemisahan senyawa-senyawa berdasarkan perbedaan kecepatan mobilitas ion karena adanya perbedaaan tegangan tinggi yang diberikan. Pendeteksian yang digunakan adalah secara elektrokimia dengan menggunakan elektroda kerja yaitu Boron Doped Diamond (BDD) dengan terminasi Hidrogen yaitu Hydrogenated Boron Doped Diamond (H-BDD) dan sebagai pembanding, digunakan juga elektroda kerja Oxidized Boron Doped Diamond (O-BDD). Elektoda H-BDD digunakan sebagai elektroda kerja karena dapat lebih baik mengukur puncak arus senyawa Adenosin Fosfat yaitu AMP, ADP, dan ATP dibandingkan elektroda O-BDD. Diukur pula Adenin dan Adenosin sebagai data tambahan. Puncak arus ketiga senyawa adenosine fosfat sama yaitu 1,5 Volt sehingga diperlukan metode elektroforesis untuk dapat memisahkannya. Puncak arus tertinggi didapatkan pada kodisi pH 4 dalam larutan penyangga PBS (Phosphate Buffer Saline) dengan menggunakan elektroda H-BDD sedangkan pH 2 dengan menggunakan elektroda O-BDD. Kapiler yang digunakan berupa fused silica dengan diameter dalam yaitu 50 μm dan diameter luar yaitu 150 μm. Tegangan tinggi yang digunakan sebesar 10 kV dengan menggunakan power suplai tegangan tinggi. Perlu dilakukan perbaikan rancangan elektroforesis dan beberapa kendala lain untuk menghasilkan pengukuran yang baik.
, Capillary electrophoresis is a method of separating compounds by ion mobility speed difference because of the different high voltage supplied. Detection used is electrochemically by using the working electrode is doped Boron Diamond (BDD) with Hydrogen termination, It is Hydrogenated Boron doped Diamond (H-BDD) and as a comparison, the working electrode is used also Oxidized Boron doped Diamond (O-BDD). H-BDD electrode is used as the working electrode as it can better measure the peak flow Adenosine Phosphate compounds are AMP, ADP, and ATP than O-BDD electrode. Adenine and adenosine is measured as well as additional data. The third current peak adenosine phosphate compounds are 1.5 Volt so that the necessary methods of electrophoresis to separate them. Highest peak currents obtained at pH 4 Events in PBS buffer solution (Phosphate Buffer Saline) using H-BDD electrodes while pH 2 using electrodes O-BDD. Capillaries are used in the form of fused silica with a diameter of 50 μm and the outer diameter of 150 μm. High voltage is used at 10 kV using a high voltage power supply. The need to restore the draft electrophoresis and several other obstacles to produce a good measurement.
]

 File Digital: 1

Shelf
 S60933-Muhammad Maghribul Falah.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S60933
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: Universitas Indonesia, 2015
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xviii, 46 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S60933 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20412930
Cover