UI - Disertasi Membership :: Kembali

UI - Disertasi Membership :: Kembali

Over-koreksi pada penatalaksanaan fraktur greenstick radius

Hendroyono Kumorocahyo; Nasrin Kodim, promotor; Respati Suryanto Dradjat, co-promotor; Budi Utomo, examiner; Tati L.E. rajab, examiner; Putu Astawa, examiner; Ratna Djuwita, examiner; Nurhayati Adnan, examiner; Hermawan Nagar Rasyid, examiner (Universitas Indonesia, 2012)

 Abstrak

Latar belakang: Penatalaksanaan fraktur greenstick radius sering berakibat malunion karena angulasi-ulang yang membatasi gerak sendi radio-karpal. Oleh sebab itu perlu diupayakan metoda reposisi yang aman, efektif, dan murah yang dapat dikerjakan sebagai Standar Prosedur Operasional di RSUD kabupaten Indonesia. Reposisi fraktur greenstick radius dengan melakukan over-koreksi, merupakan pilihan, karena dapat mencegah terjadinya angulasi-ulang.
Tujuan: Menilai efektivitas dan keamanan reposisi dengan over-koreksi dalam penatalaksanaan fraktur greenstick radius.
Rancangan dan metode: Uji klinis acak, grup paralel, dengan concealment. Penelitian melibatkan 92 anak (46 per kelompok) usia 4-14 tahun dengan fraktur greenstick radius di RSUD Kota Bekasi, Agustus 2011 sampai Mei 2012. Efektivitas prosedur diukur melalui derajat residu angulasi (minimal ditetapkan 5°), angulasi ulang, pergeseran fragmen fraktur (minimal <25%), dan risiko pengobatan (untuk mengukur keamanan pasien) mulai saat setelah reposisi 24 jam, minggu pertama sampai minggu ke-4, minggu ke-6 dan minggu ke-10.
Hasil: Over-koreksi terbukti efektif dan aman digunakan dalam penatalaksanaan fraktur greenstick radius. Pada semua pengamatan, Insidens Risk untuk terjadinya residu angulasi >5° pada kelompok over koreksi lebih kecil dibandingkan kelompok tanpa over koreksi. Pada minggu kedua, IR pada kelompok over koreksi (0,04) sedangkan kelompok tanpa over koreksi (0,39) dengan Risk Difference -0,35 (95%CI: -0,50 - -0,19). Perbedaan tersebut terlihat konsisten pada seluruh pengamatan. Probabilitas kesintasan lebih besar pada kelompok over-koreksi dibanding tanpa over-koreksi untuk terjadinya angulasi ulang. Insidence Rate recurrent angulation pada kelompok over-koreksi lebih kecil dibandingkan tanpa over koreksi dengan risk difference sebesar -0,025 (95% CI: -0,02--0,03). Pada sesaat pasca reposisi hingga minggu pertama perbedaan risiko pergeseran fragmen fraktur 2:25% pada kelompok over-koreksi jauh lebih besar daripada kelompok tanpa over-koreksi namun pada minggu kedua hingga minggu kesepuluh, perbedaan risiko sudah sangat berkurang sehingga tidak didapatkan perbedaan bermakna mulai minggu kedua hingga kesepuluh. Proporsi risiko pengobatan yang terjadi pada pasien sangat sedikit sehingga penelitian ini tidak dapat membuktikan bahwa pengobatan fraktur greenstick radius dengan melakukan over-koreksi lebih baik dalam mengontrol risiko pengobatan.
Kesimpulan: Over-koreksi efektif dan aman untuk digunakan dalam penatalaksanaan fraktur greenstick radius pada anak.
Saran: perlu dilakukan penelitian yang sama yang dilakukan oleh ahli bedah ortopedi lain pada beberapa RSUD di kabupaten di Indonesia;

Background: Management of greenstick radius fracture often results in malunion because re-angulations that restrictive radio-carpal joint. Therefore, needed a safer, effective, and cheaper repositioning method that can be done as a Standard Operating Procedure in district hospitals in Indonesia Reposition of greenstick radius fracture with over-correction is as choice because it can prevent re-angulations.
Objective: Asses the effectiveness and safety of repositioning with over-correction in the greenstick radius fracture management.
Design and method: Randomized clinical trial, parallel group, with concealment. This study involved 92 children (46 per group) aged 4-14 years with greenstick radius fracture in Bekasi City General Hospital, August 2011 until May 2012. Effectiveness of the procedure is measured by the degree of residual angulations (minimal <5<), re­ angulations, a shift in the fracture fragments (minimal <25%), and risk of treatment (to measure patient safety) started after 24 hours repositioning, first week until fourth, sixth and tenth week.
Result: Over-correction proved effective and safe to use in the management of greenstick radius fracture. In All observations, Incidence Risk for the occurrence of residual angulations is >5° at the over-correction group less than non over-correction group. In the second week, IR at the over-correction group (0,04), while non over­ correction (0,39) with Risk Difference -0,35 (95%CI: -0,50 - -0,19). This difference was seen consistently in all observation. Probability of survival at the over-correction group greater than non over-correction group for the occurrence of re-angulations. Incidence Rate recurrent angulations at the over-correction group less than non over correction with risk difference -0,025 (95% CI: -0,02--0,03). After reposition until the first week, the difference of fracture fragment shift's risk 2:25% at the over­ correction group, much larger than non over-correction group. But at the second week until tenth week, the difference of risk has been significantly reduced, so that there is no significant difference started at the second week until tenth week. Proportion of treatment risk occurred in patients measly, so that this study cannot prove that the greenstick radius fracture treatment with over-correction better in control the risk of treatment.
Conclusion: Over-correction is effective and safe to use in the management of greenstick radius fracture at the children.
Suggestion: needs to conduct the same research done by other orthopedic surgeons at several district hospitals in Indonesia.

 File Digital: 1

Shelf
 D2025-Hendroyono Kumorocahyo.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Disertasi Membership
No. Panggil : D2025
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Jakarta: Universitas Indonesia, 2012
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xxiii, 95 pages ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Perpustakaan Universitas Indonesia
Lokasi : Perpustakaan UI. Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
D2025 07-17-956378113 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20419742
Cover