UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Uji kesahihan dan keandalan uji jalan lima belas meter sebagai alat ukur kapasitas fungsional osteoartritis lutut = Validity and reliability of 15 meter walk test to assess the functional capacity in patients with knee osteoarthritis

Liana Halim; I Nyoman Murdana, supervisor; Tulaar, Angela B.M., supervisor; Hamzah Shatri, supervisor; Siti Anissa Nuhonni, examiner ([Publisher not identified] , 2015)

 Abstrak

ABSTRAK
Latar Belakang: Osteoartritis (OA) merupakan penyakit sendi degeneratif yang
berkaitan dengan kerusakan kartilago sendi, paling sering mengenai sendi lutut.
Gejala yang dominan adalah nyeri dan kelemahan otot yang menyebabkan
penurunan kapasitas fungsional. Kemampuan berjalan merupakan salah satu
kapasitas fungsional pada OA lutut yang dapat diukur dengan uji jalan. Penelitian
ini bertujuan untuk menilai kesahihan dan keandalan uji jalan 15 meter untuk
mengukur kapasitas fungsional pasien OA lutut.
Metode: Desain studi potong lintang. Penelitian dilakukan terhadap 42 pasien OA
lutut yang didapat secara konsekutif. Kapasitas fungsional subjektif dinilai dengan
kuesioner Indeks Lequesne. Kapasitas fungsional objektif dinilai mengunakan uji
jalan 15 meter dengan mengukur kecepatan jalan. Penilaian uji kesahihan
menggunakan korelasi Pearson antara kecepatan jalan 15 meter dengan Indeks
Lequesne. Penilaian uji keandalan intrarater dan inter-rater menggunakan
Intraclass Correlation Coefficient (ICC).
Hasil: Didapatkan korelasi negatif kuat bermakna antara kecepatan jalan 15 meter
dengan Indeks Lequesne (r= -0,62, p=0,000). Nilai keandalan intrarater ICC 0,990
(Rentang kepercayaan 95% 0,981-0,995, p= 0,000). Nilai keandalan inter-rater
ICC 0,999 (Rentang kepercayaan 95% 0,998-0,999, p= 0,000).
Simpulan: Uji jalan 15 meter terbukti sahih dan andal untuk mengukur kapasitas fungsional pasien OA lutut.

ABSTRACT
Background: Osteoarthritis (OA), a degenerative joint disease, is associated with
a breakdown of cartilage in the joints, with the knee being the most commonly
affected joint. Symptoms include pain and muscle weakness which cause
declining functional capacity. Walking ability, one of the functional capacities of
patients with knee OA, is measurable using walk test. The aim of the study was to
look at the validity and reliability of 15-meter walk test to measure the functional
capacity of patients with OA of the knee.
Methods: The study was a cross sectional study which looked at 42 consecutive
knee OA patients. Functional capacity of these patients were evaluated
subjectively using Lequesne Index questionnaire. In addition, functional capacity
was measured objectively using 15-meter walk test by measuring their walking
speed. Validity was evaluated using Pearson correlation coefficient between the
15-meter walk test and Lequesne Index questionnaire. Intrarater and inter-rater
reliability was assessed using Intraclass Correlation Coefficient (ICC).
Results: There was a significant negative correlation between 15-meter walk test
and Lequesne Index questionnaire (r= -0,62, p=0,000). Intrarater ICC reliability
score 0,990 (95% confidence interval 0,981-0,995, p=0,000). Inter-rater ICC
reliability score 0,999 (95% confidence interval 0,998-0,999, p=0,000).
Conclusions: 15-meter walk test was proven to be valid and reliable to assess the functional capacity of patients with OA of the knee.

 File Digital: 1

Shelf
 SP-Liana Halim.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2015
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 50 pages : illusttation ; 28 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-Pdf 16-18-177779943 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20424543