UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Gambaran konsentrasi pajanan personal particulate matter 2,5 (PM2,5) dan efek akut pernapasan subyektif pada pekerja patrol bagian produksi di industri semen PT X, tahun 2016 = Description of personal exposure particulate matter 2,5 (PM2,5) concentration and subjective acute respiratory effect on patrol workers production at cement industry PT X, 2016

Anisa Kurniati; Doni Hikmat Ramdhan, supervisor; Mila Tejamaya, examiner; Hifni Baihaqi examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2016)

 Abstrak

Particulate matter merupakan salah satu kontaminan udara yang dihasilkan oleh industri semen. Pajanan jangka panjang ataupun jangka pendek PM2,5 mengakibatkan efek kesehatan, salah satunya gangguan fungsi pernapasan. Penelitian ini bertujuan untuk menggambarkan konsentrasi pajanan personal PM2,5 dan efek akut pernapasan subyektif pada pekerja patrol bagian produksi di industri semen PT X, tahun 2016. Penelitian ini merupakan penelitian kuantitatif dengan desain deskriptif . Pengukuran konsentrasi PM2,5 menggunakan Leland Legacy Pump dan Sioutas Cascade Impactor selama 8 jam kerja pada patroler area reklamer, raw mill, firing, finish mill, dan packhouse. Hasil penelitian menunjukkan rata-rata konsentrasi pajanan personal PM2,5 pada patroler industri semen PT X adalah 1495,651 µg/m3 dan konsentrasi pajanan PM2,5 tertinggi terdapat pada area packhouse. Seluruh patroler mengalami efek akut pernapasan subyektif, dengan keluhan tertinggi sakit tenggorokan dan bersin (64,7%).

Particulate matter is one of the air contaminant produced by cement industry. Health effect that caused by long term or short term of PM2,5 exposure lead to respiratory diseases. This study purposes to describe personal exposure concentrations of particulate matter (PM2,5) and percentage subjective acute respiratory effects on production patrol workers at PT X cement industry 2016. This research is a quantitative descriptive study by measuring the concentration of PM2,5 using personal sampling equipment such as Leland Legacy Pump and Sioutas Cascade Impactor during work hours on patrol reklamer, raw mill, firing, finish mill, and pack house work area. The result shown that the average personal exposure concentration of PM2,5 on patrol workers in PT X cement industry amounted to 1495,651 µg/m3 with the highest area of exposure in the pack house work area. All of patrol workers experienced the subjective acute respiratory effects with the highest effect are sore throat and sneezing (64,7%).

 File Digital: 1

Shelf
 S65317-Anisa-Kurniati.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S65317
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2016
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvii, 125 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S65317 14-18-741337074 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20429786
Cover