UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Analisis efisiensi karbon aktif dari kompos untuk penyisihan logam berat kromium heksavalen pada air lindi TPA Cipayung = Analysis of compost based activated carbon efficiency for reducing heavy metal chromium hexavalent in leachate of Cipayung landfill

Sunartriasih; Cindy R. Priadi, supervisor; El Khobar Muhaemin Nazech, examiner; Heni Suseno, supervisor ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Air lindi TPA Cipayung dilakukan pengujian adsorpsi menggunakan karbon aktif dari kompos (KAK) karena masih terlampauinya konsentrasi kromium heksavalen (Cr VI) di atas baku mutu. Uji adsorpsi dilakukan melalui metode uji batch dan uji kolom untuk diketahui efisiensi penyisihannya pada efluen. Uji batch (dosis 2,5 g/L dan 0,5 g/L) dilakukan pada kecepatan pengadukan 50 rpm untuk waktu 20-100 menit. Persentase penyisihan mencapai 96% untuk dosis KAK 2,5 g/L, dan 81% untuk dosis KAK 0,5 g/L. Pada uji kolom dengan dosis KAK 17,4 g/L, persentase penyisihan terbesar yang didapat adalah 100% pada percobaan 2 (jam ke- 6 s/d 12) untuk kedalaman 80 cm, dan yang terkecil adalah 77% pada percobaan 3 (jam ke- 12 s/d 18) untuk kedalaman 20 cm. Hasil menujukkan bahwa uji batch memiliki efisiensi penyisihan yang lebih baik yaitu dengan kapasitas adsorpsi yang sebesar 1,79 mg/g dan dosis KAK hanya 0,5 g/L, dibandingkan dengan uji kolom yang hanya memiliki kapasitas adsorpsi terbesar 1,43 μg/g dengan dosis KAK yang sebesar 17,4 g/L.

ABSTRACT
The leachate from Cipayung landfill was undergone an adsorpstion test using a compost-based activated carbon (CBAC) due to the exceeding concentration of hexavalent chromium (Cr VI) from the threshold limit. The test was done through batch testing and column testing method for its reduction efficiency being evaluated. The batch testing method (dose of 2,5 g/L and 0,5 g/L) was done in mixing gradient velocity of 50 rpm for range time of 20 to 100 minutes. Reduction efficiency of 96% was achieved for CBAC dose of 2,5 g/L, and 81% for CBAC dose of 0,5 g/L. In the column test using 17,4 g/L CBAC dose, the achieved highest reduction was 100% in the 2nd testing (6-12 hours) for CBAC depth of 80 cm, and the lowest was 77% in the 3rd testing (12-18 hours) for CBAC depth of 20 cm. The result showed that batch method has the better removsl efficiency with an adsorption capacity of 1,79 mg/g and CBAC dose which is only 0,5 g/L, compared to the column method which adsorption capacity is 1,43 μg/g with the CBAC dose as big as 17,4 g/L.;

 File Digital: 1

Shelf
 S64724-Sunartriasih.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S64724
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvii, 123 pages : illustration ; 21 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S64724 14-18-296501713 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20431411
Cover