UI - Tesis Membership :: Back

UI - Tesis Membership :: Back

Kesesuaian sonotubometri dengan timpanometri sebagai pemeriksaan fungsi ventilasi tuba eustachius pada subjek dewasa pendengaran normal = Conformity between sonotubometry and tympanometry as a test of eustachian tube ventilation function in adult subjek with normal hearing / Rossa Martiastini Ajiati

Rossa Martiastini Ajiati; Jenny Bashiruddin; Widayat Alviandi, supervisor; Joedo Prihartono, supervisor; Dini Widinarsih, examiner; Brastho Bramantyo, examiner; Hutauruk, Syahrial M., examiner ([Publisher not identified] , 2016)

 Abstract

ABSTRAK
Latar belakang. Sonotubometri merupakan tes fungsi ventilasi TE berdasarkan
prinsip kerjanya merupakan tes fungsi ventilasi tuba Eustachius yang paling
fisiologis, mudah dikerjakan, tidak memerlukan tekanan udara yang ekstrim,
tidak invasif, dapat dikerjakan pada membran timpani yang perforasi maupun
intak dapat dikerjakan. Dalam menilai fungsi ventilasi TE, terdapat 3 parameter
yang menjadi acuan yaitu amplitudo peningkatan suara yang terekam, frekuensi
dan durasi pembukaan lumen TE. Sedangkan timpanometri menilai fungsi
ventilasi TE berdasarkan perubahan pada tekanan telinga tengah. Tujuan:
Mengetahui kesesuaian sonotubometri dan timpanometri sebagai pemeriksaan
fungsi ventilasi tuba Eustachius pada subjek dewasa pendengaran normal.
Metode: Penelitian cross sectional ini dilakukan di Poliklinik Neurootologi dan
Rinologi THT pada bulan Desember 2015-Januari 2016 pada 40 subjek dewasa
pendengaran normal dilakukan pemeriksaan fungsi ventilasi tuba menggunakan
sonotubometri dengan perasat menelan air selama 10 detik dan menggunakan
timpanometri setelah perasat Toynbee dan Valsalva dengan timpanometri. Hasil:
Dilakukan analisa perbandingan dengan uji Mc Nemar dan kesesuaian dengan uji
Kappa. Didapatkan perbedaan proporsi serta kesesuaian yang lemah antara nilai
fungsi ventilasi TE yang diperiksa dengan sonotubometri dan timpanometri
Kesimpulan: Sonotubometri dapat menjadi metode pilihan dalam menilai fungsi
ventilasi TE karena mekanisme kerja yang menilai fungsi ventilasi TE secara
langsung dan paling fisiologis

ABSTRACT
Background: Sonotubometry is ventilation function test of Eustahian tube that
has the most functional mechanism, non invasif, easy-performed, no extreme of
air pressure and can be performed in intact or perforation timpanic membran.
For ventilation function of Eustachian tube evaluation, there are 3 komponen
measurement as parameter. These are increase of acoustik intensity so called
amplitudo, frequency and the duration of Eustachian tube opening. While
tympanometry measure the ventilation function of Eustachian tube based on the
change of middle ear pressure Objective: to examine the conformity between
sonotubometri and tympanometry as a test tool of Eustachian tube ventilation
function in adult subject with normal hearing. Methods: This cross sectional
research was performed on 40 subject who has normal hearing and then
performed sonotubometri using 10 seconds wet swallong and timpanometri
examination after Toynbee-Valsava manuver. The result of examination was
statistically analyzed by Mc Nemar and Kappa.Results: Tthere was statistically
significant of different proportion and weak conformity between Eustahian tube
ventilation function based on sonotubometri and tympanometry.Conclusion:
Sonotubometry can be an option for evaluation of eustahian tube ventilation
function according to the physiologically and directly evaluation of the
mechanisme.

 Digital Files: 1

Shelf
 T-Rossa Martiastini Ajiati.pdf :: Download

LOGIN required

 Metadata

Collection Type : UI - Tesis Membership
Call Number : T-Pdf
Main entry-Personal name :
Additional entry-Personal name :
Additional entry-Corporate name :
Study Program :
Subject :
Publishing : [Place of publication not identified]: [Publisher not identified], 2016
Cataloguing Source LibUI ind rda
Content Type text
Media Type computer
Carrier Type online resource
Physical Description xviii, 115 pages : illustration ; 28 cm + appendix
Concise Text
Holding Institution Universitas Indonesia
Location Perpustakaan UI, Lantai 3
  • Availability
  • Review
  • Cover
Call Number Barcode Number Availability
T-Pdf 15-17-153066252 TERSEDIA
Review:
No review available for this collection: 20432390
Cover