Analisis pengurangan energi arc flash dengan optimasi koordinasi alat proteksi pada instalasi listrik di lapangan migas lepas pantai = Analysis of arc flash energy reduction by optimizing protection device coordinaton at electrical installation in offshore oil fied / Atas Siregar

Siregar, Atas; Iwa Garniwa M.K., supervisor; Rudy Setiabudy, examiner; Amien Rahardjo, promotor; I Made Ardita Y., examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Keselamatan dari bahaya arc flash telah menjadi persyaratan dalam pengoperasian
suatu instalasi listrik di lapangan migas lepas pantai. Kejadian arc flash tidak hanya
mengancam keselamatan pekerja dan fasilitas tersebut tetapi juga bisa mengakibatkan
kegagalan produksi yang sangat mahal. Salah satu cara untuk mengurangi bahaya arc flash
ini ialah menurunkan trip setting alat proteksi sehingga alat proteksi bisa berkerja secepat
mungkin untuk menghilangkan kejadian arc flash. Namun penurunan trip setting alat proteksi
ini harus optimal sehingga tetap bisa menjamin kehandalan alat proteksi terhadap ganguan,
selain juga bisa mengurangi energi arc flash. Pada penelitian ini dilakukan analisis
pengurangan energi arc flash dengan mengoptimasi koordinasi alat proteksi pada instalasi
listrik di lapangan ABC, sebuah lapangan migas lepas pantai di Laut Natuna. Hasil analisis
memperlihatkan energi arc flash system bisa dikurangi sampai batas yang diperbolehkan
tanpa mengorbankan kehandalan alat proteksi terhadap gangguan. Pada bagian akhir
dipaparkan analisis ekonomi yang memperlihatkan pengurangan energi arc flash dengan
optimasi koordinasi alat proteksi di lapangan migas ABC dapat diterima secara bisnis karena
memberikan keuntungan yaitu mengurangi biaya tidak tetap akibat kejadian arc flash dengan
NPV (Net Present Value) sebesar USD 675.932.

ABSTRACT
Electrical safety from arc flash hazard has become requirement for operation of an
offshore oil platform. During it?s operation, arc flash is always become potential hazard that
not only threaten personal and facility safety, but also can cause very expensive production
loss. One solution to reduce arc flash hazard is reducing protection device trip setting to
make it working faster to isolate fault. But reducing protection devices shall be optimum that
it shall be able to maintain reliability from inadvertant trip as well as reducing arc flash
energy. In this research, analysis of arc flash reduction by optimizing protection device
coordination will be conducted at electrical instalation in field ABC, offshore oil platform in
Laut Natuna. Study result shows optimizing protection device setting can reduce arc flash
incident energy till meet allowable limit without sacrifice realiability of power supply. At the
end, economical analysis is also carried out that shows above investment can be accepted due
to give benefit for preventing loss due to arc flash equivalent with cost NPV (Net Present
Value) USD 675.932.

 File Digital: 1

Shelf
 T45753-Atas Siregar.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T45753
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvi, 112 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T45753 15-17-669471722 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20432430
Cover