Nilai normal pemeriksaan ambang penghidu dengan uji penghidu intravena pada subjek dewasa tanpa gangguan penghidu di RSUPN Cipto Mangunkusumo = Normative value of olfactory threshold using intravenous olfaction test in adult subjects with normal olfactory function in Cipto Mangunkusumo hospital

Tissa Indriaty; Retno S. Wardani, supervisor; Saptawati Bardosono, supervisor; Niken Lestari, supervisor; Umar Said Darmabakti, examiner; Dini Widiarni Widodo, examiner; Nina Irawati, examiner; Semiramis Zizlavsky, examiner; Fauziah Fardizza, examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Diagnosis gangguan penghidu memerlukan pemeriksaan yang akurat. Saat ini Departemen THT-KL RSUPN Cipto Mangunkusumo menggunakan Sniffin? Sticks sebagai pemeriksaan rutin. Uji penghidu intravena (UPI) merupakan pemeriksaan penghidu sederhana yang dapat melengkapi pemeriksaan Sniffin? Sticks dalam menilai jalur retronasal dan prognosis. Tujuan: Mengetahui sebaran nilai normal ambang penghidu berdasarkan UPI pada subjek dewasa tanpa gangguan penghidu. Metode: Penelitian potong lintang deskriptif yang dilakukan di Unit Rawat Jalan Terpadu THT-KL RSUPN Cipto Mangunkusumo periode Januari-Februari 2016 dengan melibatkan 55 subjek normosmia. Hasil: Rerata (± simpang baku) nilai normal ambang berdasarkan UPI adalah 16,29 ± 5,52 detik dengan persentil 5 pada 9,46 detik dan persentil 90 pada 22,99 detik. Tidak terdapat korelasi antara hasil pemeriksaan ambang penghidu berdasarkan UPI dengan ambang penghidu maupun skor total pemeriksaan Sniffin? Sticks. Kesimpulan: Uji penghidu intravena dapat diaplikasikan dalam evaluasi fungsi penghidu sebagai pelengkap Sniffin? Sticks.

ABSTRACT
Background: The diagnosis of olfactory loss needs accurate examinations. At this moment, Department of Otolaryngology Head and Neck Surgery (ORL-HNS) has used Sniffin? Sticks as a routine examination. Intravenous olfaction test (IOT) is a simple examination to complement the Sniffin? Sticks examination( due to its ability to evaluate retronasal pathway and prognosis. Objective: To investigate the normative value of olfactory threshold using the IOT in adult subjects without olfactory loss. Method: This research is a cross sectional, descriptive study took place at ORL-HNS Outpatient Clinic of Cipto Mangunkusumo Hospital included 55 normosmia subjects in January-February 2016. Results: Normative value of olfactory threshold using IOT was 16,29 ± 5,52 seconds (mean ± standard deviation) with the 5th percentile on 9,46 seconds and 90th percentile on 22,99 seconds. There was no correlation between the olfactory threshold results based on IOT with the olfactory threshold or the overall score of Sniffin? Sticks. Conclusion: Intravenous olfactory test is applicable for the evaluation of olfactory function, complementing the Sniffin? Sticks examination.

 File Digital: 1

Shelf
 SP-Tissa Indriaty.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xxiii, 75 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-17-343247403 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20435310
Cover