Analisis struktur bangunan 25 lantai dengan flat plate terhadap beban gempa pada wilayah risiko seismik tinggi dan risiko seismik menengah = Strctural analysis of building structure 25 story with flat plate to lateral load on high seismic risk region and medium seismic region

Fadhil Dzulfikar; Sjahril A. Rahim, supervisor; Yuskar Lase, examiner; Essy Arijoeni Basoenondo, examiner ([Publisher not identified] , 2017)

 Abstrak

ABSTRAK
Struktur flat plate pada wilayah gempa tinggi di Indonesia masih jarang digunakan karena lemah terhadap geser pada sambungan kolom-slab. Dengan demikian dalam melakukan perencanaan struktur flat plate pada wilayah gempa tinggi harus dikombinasikan dengan sistem struktur penahan beban lateral yaitu kombinansi dinding geser struktural khusus dan perimeter frame SRPMK . Struktur flat plate hanya didesain sebagai struktur penahan beban gravitasi. Hubugan kolom-slab harus memiliki kapasitas untuk mampu mengikuti deformasi yang telah diperbesar oleh faktor defleksi Cd akibat beban gempa. Proporsi dimensi kolom akan menentukan besarnya gaya lateral yang diterima oleh kolom tersebut. Semakin kecil dimensi kolom maka semakin kecil gaya lateral yang diterima oleh kolom tersebut. Pada wilayah gempa menengah struktur flat plate dapat digunakan sebagai bagian dari sistem penahan beban lateral. Dalam perencanaan ini struktur flat plate dimodelkan sebagai equivalent slab-beam yang merupakan bagian sistem rangka pemikul momen menengah. Sistem penahan beban lateral pada perencanaan pada wilayah gempa menengah merupakan kombinasi dari dinding geser struktural khusus, perimeter frame SRPMM dan slab-column frame SRMM . Dari hasil analisa didapatkan bahwa jika perencanaan mengikuti kaidah perencanaan tersebut maka flat plate dapat digunakan pada wilayah gempa tinggi dan menengah dan struktur masih bersifat daktail.

ABSTRACT
Flat plate structure for high seismic risk region in Indonesia is not commonly used because it has high risk on shear failure on the slab column connection. Therefore the building design in high seismic risk region should be combined with lateral resisting system, a dual system combining shearwall and perimeter frame SMRF . Flat plate structure is only designed as gravity resisting system. Slab column connection should have capacity to follow the bigger deformation by deflection factor Cd caused by lateral force. The proportion of the interior column dimension would determine the amount of lateral force received. The smaller the column dimension, the smaller the lateral force accepted by the column itself. In an region with medium seismic risk, flat plate structure can be used as component to resist lateral force. In this kind of design, flat plate is modeled as equivalent slab beam which also a part of slab column moment frames. Lateral resisting system component in the medium seismic risk region is a combination of shear wall and slab column moment frames IMRF . From this design, the writer found that if the design follow the guidelines plan, the flat plate can be used both in high seismic risk region and medium seismic risk region and structure is still ductile.

 File Digital: 1

Shelf
 S66427-Fadhil Dzulfikar.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S66427
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2017
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xviii, 174 pages ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S66427 14-19-982119102 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20445521
Cover