UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Algoritme elektrokardiografi sederhana untuk menentukan lokasi jaras tambahan accessory pathway pada pasien dengan sindrom wolff-parkinson-white = Simple electrocardiography algorithm for localizing accessory pathway in patients with wolff parkinson white syndrome

Ardhestiro Harnindyo Putro; Sunu Budhi Raharjo, supervisor; Anwar Santoso, supervisor; Budi Setianto, examiner; Irmalita, examiner; Nur Haryono, examiner (Fakultas Kedokteran Universitas Indonesia, 2017)

 Abstrak

Latar Belakang : Telah banyak dipublikasikan berbagai macam algoritme untukmenentukan lokasi jaras tambahan pada pasien dengan sindroma Wolff-ParkinsonWhite.Algoritme-algoritme tersebut memiliki akurasi yang baik meskipunmemiliki alur yang komplek dan sulit untuk diingat. Berbagai macam algoritmeyang berkembang menggunakan morfologi delta wave dan polaritas komplek QRSdalam penyusunannya. Dengan adanya teknologi kateter ablasi yang ada saat inialgoritme yang komplek tidak diperlukan lagi. Diperlukan suatu algoritme yangsederhana, memiliki akurasi yang baik dan mudah diingat. Penelitian ini bertujuan untuk menilai akurasi algoritme sederhana untuk memprediksi lokasi jarastambahan.
Metode : Penelitian ini merupakan studi potong lintang yang dilakukan diDepartemen Kardiologi dan Kedokteran Vaskuler FKUI/ Pusat Jantung NasionalHarapan Kita PJNHK. Data yang diambil berupa elektrokardiografi EKG pada67 pasien dengan sindroma Wolff-Parkinson-White yang menjalani tindakan ablasiperiode Januari 2014 - Oktober 2016. Data EKG yang terkumpul dibacaberdasarkan algoritme baru oleh dua orang penilai independen kemudiandibandingkan dengan hasil ablasi pada tabel 2x2.
Hasil Penelitian : sampel akhir sebanyak 47 data hasil bacaan EKG observerterpercaya dihitung berdasarkan tabel 2x2 dengan hasil ablasi. Hasil menunjukkanalgoritme ini memiliki sensitivitas left free wall 45, septal 80, right free wall92, spesifisitas left free wall 96, septal 69, right free wall 85. Nilai dugapositif NDP left free wall 90, septal 55, dan right free wall 67. Nilai duganegatif NDN left free wall 70, septal 88, dan right free wall 97. Akurasialgoritme bervariasi dari 73 -87. Didapatkan perhitungan kesepahaman antarpenilai dengan nilai kappa 0,74-0,93. Perhitungan likelihood ratio menunjukkanlikelihood ratio positif left free wall 11,23, septal 2,23, dan right free wall 6,57.Likelihood ratio negatif left free wall 0,57, septa 0,28, dan right free wall 0,09.
Kesimpulan : Algoritme baru yang lebih sederhana ini memiliki akurasi yang baikdengan angka kesepahaman antar penilai yang baik sehingga dapat digunakansecara umum.

Background : A lot of algorithms in localizing accessory pathway AP in patientswith Wolff Parkinson White Syndrome have been published. Although many ofthose methods have high accuracy, they are complicated and difficult to memorize.Most of the established algorithm use delta wave morphology and QRS polarity todetermine the location. With the technology of catheter ablation nowadays suchcomplex algorithms are not really needed. This study aim to investigate theaccuracy of a simple algorithm to predict the location of accessory pathways.
Methods : This was a cross sectional study conducted in the NationalCardiovascular Center Harapan Kita RSJPDHK Department Cardiology andVascular Medicine, FMUI. The electrocardiography ECG findings of 67 patientswith Wolff Parkinson White syndrome underwent ablations from January 2014until October 2016 were used in the current study. Those ECGs were analyzed usingthe new algorithm and were evaluated by two independent observers and comparedwith ablation results in a 2x2 table.
Results : The final number of samples was 47 ECGs. The algorithm showed it hada sensitivity of 45 on left free wall, 80 on septal, 92 on right free wall APs inaddition to the specificity of 96 on left free wall, 69 on septal, 85 on right freewall APs. Positive predictive value PPV were 90 on left free wall, 55 on septaland 67 on right free wall APs. Negative predictive value NPV were 70 on leftfree wall, 88 on septal and 97 on right free wall APs. Algorithm accuracy variedfrom 73 to 87. Inter observer agreement calculation was a kappa of 0.74 mdash 0.93.Likelihood ratio calculation identified the positive likelihood ratio of 11.23 on leftfree wall, 2.23 on septal and 6.57 on right free wall APs and negative likelihoodratio of 0.57 on left free wall, 0.28 on septal and 0.09 on right free wall APs.
Conclusion : This new and simple algorithm provide a remarkable accuracy with agood inter observer agreements. Therefore this algorithm is potential to beimplemented in general practice.

 File Digital: 1

Shelf
 SP-Ardhestiro harnindyo putro.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : T55653
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Program Studi :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2017
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvii, 46 pages : illustration ; 29 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T55653 16-18-138700336 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20447279
Cover