Pengaruh rotasi kepala kontra lateral terhadap jarak dan overlapping vena jugularis interna dan arteri karotis: pengukuran setinggi kartilago krikoid dengan bantuan ultrasonografi pada ras Melayu di Indonesia = The effect of contra lateral head rotation on distance and overlapping internal jugular vein and carotid artery observation at cricoid level by ultrasound guidance on the Malay Race in Indonesia

Hadli Rokyama; Aldy Heriwardito, supervisor; M. Ruswan Dachlan, supervisor; Indro Mulyono, examiner; Rudyanto Sedono, examiner; Adhrie Sugiarto, examiner (Fakultas Kedokteran Universitas Indonesia, 2017)

 Abstrak

ABSTRAK
Latar belakang: Penggunaan kateter vena sentral yang semakin banyak seiring meningkatnya mutu pelayanan kesehatan di kamar operasi dan ruang rawat intensif membuat risiko komplikasi juga semakin meningkat. Ultrasonografi direkomendasikan untuk menurunkan insiden komplikasi kanulasi vena jugularis interna. Namun, keterbatasan akses dan ketersedian ultrasonografi membuat metode penanda anatomi masih diminati walaupun insiden komplikasi mencapai 19 Merrer, 2011 , sehingga posisi yang tepat diharapkan dapat mengurangi insiden komplikasi. Rotasi kepala pada sudut tertentu mempengaruhi posisi vena jugularis interna dan arteri karotis. Penelitian ini bertujuan ingin mengetahui pengaruh rotasi kepala kontra lateral terhadap jarak dan overlapping vena jugularis interna terhadap arteri karotis setinggi kartilago krikoid dengan bantuan ultrasonografi pada ras Melayu di Indonesia.Metode: Penelitian ini bersifat analitik observasional denga rancangan potong lintang pada pasien yang menjalani operasi bedah terencana di Instalasi Bedah Pusat RSUPN Ciptomangunkusumo Jakarta. Setelah mendapatkan izin komite etik dan informed consent sebanyak 34 subyek diambil dengan metode consecutive sampling pada bulan Oktober 2016. Jarak dan rasio overlapping vena jugularis interna terhadap arteri karotis setinggi kartilago krikoid diukur dengan menggunakan ultrasonografi dua dimensi pada sudut rotasi kontra lateral 0o, 30o, 45o, 60o. Data diolah menggunakan program SPSS 21. Uji Anova digunakan untuk melihat hubungan jarak vena dan rasio overlapping jugularis interna terhadap arteri karotis dilanjutkan dengan uji post hoc Tukey.Hasil: Terdapat perbedaan yang bermakna jarak dan overlapping vena jugularis interna dan arteri karotis setinggi kartilago krikoid pada ras Melayu di Indonesia pada sudut rotasi kepala kontra lateral 0o, 30o, 45o, 60o p < 0,001 . Terdapat hubungan antara berat badan dan tinggi badan terhadap rasio overlapping vena jugularis interna dan arteri karotis. Tidak Terdapat hubungan antara jenis kelamin, usia dan Indeks Massa Tubuh IMT terhadap rasio overlapping vena jugularis interna dan arteri karotis.Simpulan: Terdapat pengaruh rotasi kepala kontra lateral terhadap jarak dan overlapping vena jugularis interna dan arteri karotis setinggi kartilago krikoid dengan bantuan ultrasonografi pada ras Melayu di Indonesia.Kata kunci: rotasi kepala kontra lateral, jarak dan overlapping vena jugularis interna dan arteri karotis, ras Melayu ABSTRACT Background The use of central venous catheters are widely increasing as well as improvement of health care quality in the operating theather and the intensive care unit. Complication incidences also increasing too. Ultrasound is recommended to decrease complication of internal jugular vein cannulation. However, limited access and availability to ultrasound makes anatomical landmark methods still in demand even though the incidence of complications was 19 Merrer, 2011 , exact position is expected to reduce the incidence of complications. Certain head rotation the position of the internal jugular vein and carotid artery. This study aims the effect of contra lateral head rotation to distance and overlapping of internal jugular vein and carotid artery at cricoid cartilage level by ultrasound guidance on the Malay race in Indonesia. Methods This study was analytical observational with cross sectional design in patients undergone elective surgery at Central Surgery Unit RSUPN Ciptomangunkusumo Jakarta. After getting approval from ethics committee and informed consent, 34 subjects were taken with consecutive sampling method in October 2016. Distance and overlapping ratio the internal jugular vein to carotid artery at cricoid level was measured using two dimensional ultrasound in contra lateral head rotation angle of 0o, 30o, 45o, 60o. The data were processed using SPSS 21. Anova test used to view the relationships within the vein and internal jugular overlapping ratio of the carotid artery followed by post hoc Tukey test. Results There were significant differences on distance and overlapping of the internal jugular vein and carotid artery at cricoid level on the Malay race in Indonesia at contra lateral head rotation angle 0o, 30o, 45o, 60o p

 File Digital: 2

Shelf
 SP-PDF-Hadli_Rokyama.pdf :: Unduh
 SP-PDF-Hadli_Rokyama.pdf :: Unduh

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : T55670
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: Fakultas Kedokteran Universitas Indonesia, 2017
Bahasa : Ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 44 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan