UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Optimasi distribusi cooling pada shore to ship power supply menggunakan simulasi flovent = Optimization cooling distribution of shore to ship power supply with flovent simulation

Muhammad Fikri; Nasruddin, supervisor; Muhammad Idrus Alhamid, examiner; Budihardjo, examiner; Ahmad Indra Siswantara, examiner ([Publisher not identified] , 2014)

 Abstrak

ABSTRAK
Inovasi terbaru untuk mengurangi emisi kapal laut adalah dengan menggunakan Shore to Ship Power Supply. Shore power supply akan memberikan semua energi listrik yang dibutuhkan kapal saat berlabuh. Membuat pelabuhan lebih nyaman dan bebas emisi yang dikeluarkan oleh kapal. Ada kaitan erat antara perkembangan peralatan listrik dengan industri HVAC dan perlu sinergis satu sama lain. Dimana peralatan listrik harus membutuhkan kondisi udara yang ideal agar dapat bekerja maksimal terus menerus, dan HVAC menggunakan listrik sebagai sumber energi. Dengan memaksimalkan desain yang sesuai kita dapat membuat suatu sistem yang hemat energi dan ramah lingkungan. Akan dibahas berbagai sistem distribusi cooling yang memungkinkan terhadap shore power supply, pembahasan metode distribusi juga dilengkapi hasil simulasi Flovent, dan akan dilakukan penilaian mana distribusi yang paling efisien untuk shore power supply.

ABSTRACT
The latest innovation to reduce ship emissions is to use Shore to Ship Power Supply. Shore power supply will provide all required electrical energy when the ship docked. Make the port more comfortable and freely emitted by ships. There is a strong connection between the development of electrical equipment and the HVAC industry, so they need to be synergistic with each other. Electrical equipment should require ideal conditions of the air in order to work optimally and continuously, and HVAC use electricity as an energy source. By maximizing the appropriate design we can create a system that is energy efficient and environmental friendly. We will discuss various cooling distribution system that allows the shore power supply to run optimally. With simulation results of Flovent, and assessment will be carried out to create the most efficient cooling distribution of shore power supply.

 File Digital: 2

Shelf
 S66947-Muhammad fikri .pdf :: Unduh
 S66947-Muhammad fikri .pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S66947
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2014
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xv, 62 pages : illustration ; 29 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S66947 14-19-707079087 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20460920
Cover