UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pengaruh Distorsi Radiograf Sefalometri Lateral Akibat Kemiringan Kepala pada Sumbu Anteroposterior terhadap Distorsi Pengukuran Angular Sefalometri = Effect of Distortion of Lateral Cephalometric Radiographs Due to Head Tilting on Anteroposterior Axis Against Distortion of Cephalometric Angular Measurement

Handita Permata Sari; Syurri Innaddinna Syahraini, supervisor; Menik Priaminiarti, supervisor; Hanna Bachtiar, examiner; Heru Suryonegoro, examiner (Fakultas Kedokteran Gigi Universitas Indonesia, 2017)

 Abstrak

Latar Belakang: Kesalahan posisi kepala dalam sefalostat saat pembuatan radiografis sefalometri lateral mengakibatkan distorsi pada radiograf yang dihasilkan. Hal ini mempengaruhi pada diagnosis dan rencana perawatan orthodonti pasien.
Tujuan: Mengetahui pengaruh distorsi radiografis sefalometri lateral akibat kemiringan kepala pada sumbu anteroposterior terhadap distorsi pengukuran angular sefalometri lateral.
Metode: Radiografis sefalometri lateral terhadap 7 kranium dengan sudut sebesar 0 , -20 , -15 , -10 , -5 , 5 , 10 , 15 , dan 20 terhadap sumbu anteroposterior. Radiograf dilakukan analisis sefalometri oleh dua orang pengamat. Uji reliabilitas dilakukan dengan uji Bland Altman. Uji kemaknaan dilakukan dengan uji T Berpasangan dan uji Wilcoxon.
Hasil: Terdapat perbedaan bermakna antara pengukuran 8 parameter sudut dengan kemiringan kepala lebih dari 10 p.

Background: Head position errors in the cephalostate during the lateral cephalometric projection result in radiographic distortion. This may affect the diagnosis and treatment plan of orthodontic patient's.
Objective: To discover the effect of lateral cephalometric radiograph distortion due to head tilting on the anteroposterior axis against distortion of lateral cephalometric angular measurements.
Methods: Lateral cephalometric radiograph of 7 human dry skulls with tilting angle of 0 , 20 , 15 , 10 , 5 , 5 , 10 , 15 , and 20 to the anteroposterior axis. Radiographs were analyzed by two observers. Reliability test is done by Bland Altman test. The significance test is done by paired T test and Wilcoxon test.
Results: There was a significant difference between the measurement of 8 angle parameters with head tilting greater than 10 p

 File Digital: 1

Shelf
 S-Handita Permata Sari.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Program Studi :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xv, 50 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-18-487719480 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20466606
Cover