Artikel Jurnal :: Kembali

Artikel Jurnal :: Kembali

Evaluation of Acoustic Radiation Force Impulse (ARFI) for fibrosis staging in chronic liver diseases

by Rino A. Gani, Irsan Hasan, Andri Sanityoso, Cosmas Rinaldi A Lesmana, Juferdy Kurniawan, Chyntia Olivia Maurine Jasirwan, Kemal Fariz Kalista, Lutfie (University of Indonesia. Faculty of Medicine, 2017)

 Abstrak

Background: acoustic radiation force impulse (ARFI) is a new proposed noninvasive method for liver fibrosis staging. Integrated with B mode ultrasonography, ARFI can be used to assess liver tissue condition. However its diagnostic accuracy is still being continuously evaluated. Also, there is lack of data regarding the utilization of ARFI in our population. This study aimed to evaluate the diagnostic value of ARFI as an alternative noninvasive modality for fibrosis staging in chronic hepatitis B and hepatitis C patients in our population.
Methods: we conducted cross sectional comparison of ARFI imaging and transient elastography on patients who underwent liver biopsy at Cipto Mangunkusumo Hospital. Fibrosis staging using METAVIR scoring system presented as standard reference. A total of 43 patients underwent liver biopsy was evaluated by ARFI imaging and transient elastography. Cut off values were determined using receiver operating characteristic (ROC).
Results: both liver stiffness determined by ARFI and transient elastography (TE) were moderately correlated with METAVIR score with value of 0.581 and 0.613, respectively (both P<0.01). Diagnostic accuracy of ARFI predicted significant fibrosis (F>2) with area under receiver operating characteristic curve (AUROC) of 0.773 (95% CI 0.616-0.930) and even better for cirrhosis (F4 fibrosis), expressed as AUROC of 0.856 (95% CI 0.736-0.975). Transient elastography was better for significant fibrosis with AUROC of 0.761 (95% CI 0.601-0.920) and was best for prediction of cirrhosis, expressed as AUROC of 0.845 (95% CI 0.722-0.968).
Conclusion: ARFI is provided with more convenient evaluation of liver tissue condition, and its diagnostic accuracy is not significantly different from TE for staging liver fibrosis.

 Metadata

Jenis Koleksi : Artikel Jurnal
No. Panggil : 616 UI-IJIM 49:2 (2017)
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Jakarta: University of Indonesia. Faculty of Medicine, 2017
Sumber Pengatalogan : LibUI eng rda
ISSN : 01259326
Majalah/Jurnal : The Indonesian Journal of Internal Medicine
Volume : Vol. 49, No. 2, April 2017: hal. 128-135
Tipe Konten : text
Tipe Media : unmediated
Tipe Carrier : volume
Akses Elektronik :
Institusi Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 4, R. Koleksi Jurnal
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
616 UI-IJIM 49:2 (2017) 03-18-905683829 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20472046
Cover