Hubungan konsentrasi formaldehid dalam ruang dengan gangguan fungsi paru obstruktif pada siswa sekolah menengah pertama (SMP) di Depok tahun 2018 = Association between indoor formaldehyde concentrations with obstructive pulmonary function impairment among junior high school students in Depok year of 2018

Leviani Kristiana; Bambang Wispriyono, supervisor; Budi Hartono, examiner; Satria Pratama, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2018)

 Abstrak

Latar Belakang: Salah satu polutan indoor yang menjadi masalah kesehatan masyarakat adalah formaldehid. Pemajanan formaldehid dalam ruang dapat menyebabkan gangguan fungsi paru. Anak-anak dan remaja menghabiskan sebagian besar waktunya di lingkungan indoor terutama di sekolah.
Tujuan: Mengetahui hubungan antara konsentrasi formaldehid dalam ruang dengan gangguan fungsi paru obstruktif pada siswa Sekolah Menengah Pertama SMP di Depok tahun 2018.
Metode: Studi cross-sectional potong lintang dilakukan di tiga SMP Depok. Sampel penelitian adalah 150 siswa yang diambil dengan multistage sampling. Pengukuran konsentrasi formaldehid menggunakan alat direct reading yaitu FormaldemeterTM htv dan kondisi fungsi paru diperoleh melalui pemeriksaan dengan alat spirometer. Analisis secara bivariat dengan metode chi square.
Hasil: Nilai rata-rata konsentrasi formaldehid adalah 0,038 ppm dan fungsi paru FEV1/FVC siswa SMP di Depok yaitu 94,31. Tidak ditemukan hubungan yang signifikan antara konsentrasi formaldehid dalam ruang dengan gangguan fungsi paru obstruktif. Tidak ada hubungan yang signifikan antara faktor risiko lain status gizi, aktivitas fisik, perilaku merokok, perokok dalam rumah, dan penggunaan obat nyamuk dengan gangguan fungsi paru obstruktif. Siswa dengan aktivitas fisik yang rendah berisiko 1,253 kali mengalami gangguan fungsi paru obstruktif dibandingkan siswa yang aktivitas fisiknya cukup CI: 0,203-7,725. Siswa yang menggunakan obat nyamuk berisiko 1,898 kali mengalami gangguan fungsi paru obstruktif dibandingkan dengan siswa yang tidak menggunakan obat nyamuk CI: 0,308-11,705.
Kesimpulan: Konsentrasi formaldehid pada SMP di Depok masih berada di bawah Nilai Ambang Batas dan tidak ditemukan hubungan yang signifikan dengan gangguan fungsi paru obstruktif. Perlu dilakukan penelitian lanjutan dengan gejala kesehatan lain yang disebabkan oleh pajanan formaldehid dan uji fungsi paru jenis lainnya.

Background: One of the indoor pollutants that is a public health problem is formaldehyde. Formaldehyde exposure may cause lung function impairment. Children and adolescents spend most of their time in indoor environments, especially in schools.
Objective: To examine the association between indoor formaldehyde concentrations with obstructive pulmonary function impairment among Junior High School students in Depok, 2018.
Methods: Cross sectional studies were conducted at three SMP in Depok. Sample of research is 150 students taken with multistage sampling. Measurement of formaldehyde concentrations using direct reading tool FormaldemeterTM htv and condition of lung function obtained through inspection with spirometer. Bivariate analysis with chi square method.
Results: Mean value of formaldehyde concentration is 0,038 ppm and mean lung function FEV1 FVC of Junior High School students in Depok was 94,31. There was no significant association between indoor formaldehyde concentrations with obstructive pulmonary function impairment. There was no significant association between other risk factors nutritional status, physical activity, smoking behavior, smokers in the house and the use of mosquito repellent with obstructive pulmonary function impairment. Students with low physical activity at risk 1,253 times higher to experience obstructive pulmonary function impairment than students with moderate physical activity CI 0.203 7.725. Students using mosquito repellent at risk 1,898 times higher than did not use mosquito repellent CI 0,308 11,705.
Conclusion: The concentration of formaldehyde at SMP in Depok remained below the Threshold Value and no significant association was found with obstructive pulmonary function impairment. It is strongly recommended to do further research with other health symptoms caused by formaldehyde exposure and other types of lung function tests.

 File Digital: 1

Shelf
 Leviani Kristiana.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2018
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 78 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-21-267540676 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20473955
Cover