UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Rotational Angiography Dose Index (RADI) untuk pesawat angiografi rotasi 3 dimensi: studi pendahuluan = Rotational Angiography Dose Index (RADI) in three-dimensional rotational angiography: preliminary study

Amalia Rosa; Lubis, Lukmanda Evan, supervisor; Djarwani Soeharso Soejoko, supervisor; Supriyanto Ardjo Pawiro, examiner; Dyah Palupi, examiner ([Publisher not identified] , 2019)

 Abstrak

ABSTRAK
Studi ini merupakan kajian awal teknik dosimetri yang diajukan untuk tujuan jaminan kualitas prosedur angiografi rotasi 3 dimensi (3DRA), yakni Rotational Angiography Dose Index (RADI). Metode ini mengakomodasi penggunaan dosimeter standar 10 cm untuk Cone-Beam Computed Tomography (CBCT) di 3DRA dengan berkas yang dikolimasi. Penelitian dilakukan dengan menggunakan fantom CTDI kepala dan dosimeter bilik ionisasi Radcal pada pesawat 3DRA Siemens Artis Zee. Metode yang diusulkan dalam studi ini, yakni RADI, diaplikasikan dengan variasi mode preset, lebar berkas, dan posisi dosimeter. Sebagai hasil dari penelitian ini, posisi dosimeter yang optimum untuk penentuan estimasi dosis adalah posisi Plus dan teknik dosimetri RADI dapat ditetapkan untuk jaminan kualitas. Hasil penelitian ini juga memberikan informasi faktor koreksi antara RADI dan teknik dosimetri CBDI sebesar 0.81.

ABSTRACT
This study serves as a preliminary study of proposed dosimetry techniques for quality control of 3-dimensional rotation angiography (3DRA) procedures, namely Rotational Angiography Dose Index (RADI). This method accommodates the use of a standard 10 cm dosimeter for Cone-Beam Computed Tomography (CBCT) in 3DRA with a collimated beam. The study was performed using head CTDI phantom and Radcal ionization chamber dosimeter on 3DRA feature of Siemens Artis Zee. The proposed RADI method was applied with varied preset modes, beam width, and dosimeter position. As a result of this study, the optimum dosimeter position for determining dose estimation is the Plus position, and RADI techniques can be recommended for dosimetry as part of quality assurance procedure. The study also provide information on the correction factor between RADI and CBDI dosimetry technique to be 0.81 ± 0.02.

 File Digital: 1

Shelf
 S-Pdf-Amalia Rosa.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 50 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-21-888591485 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20481876
Cover