Perbandingan nilai amplitudo dan latensi antara Elektroda Jet, Elektroda Dencott dan Elektroda Dawson-Trick-Litzkow pada pemeriksaan elektroretinografi multifokal mata normal pada populasi orang dewasa di Rumah Sakit Umum Pusat Nasional Cipto Mangunkusumo = Comparison of amplitude and implicit time between Jet Electrode, Dencott Electrode and Dawson-Trick-Litzkow Electrode in multifocal electroretinography examination in adult in Cipto Mangunkusumo National hospital

Ika Citra Susanti; M. Sidik, supervisor; Syntia Nusanti, supervisor; Aria Kekalih, supervisor; Andi Arus Victor, examiner; Gusti Gede Suardana, examiner; Yunia Irawati, examiner; Neni Anggraini, examiner; Anna Puspitasari Bani, examiner ([Publisher not identified] , 2018)

 Abstrak

ABSTRAK
Mendapatkan nilai standar normal pemeriksaan elektroretinografi multifokal dan
mencari perbandingan nilai tersebut berikut tingkat kenyamanan pasien menggunakan
elektroda Jet, Dencott dan Dawson-Trick-Litzkow pada populasi orang Indonesia
dewasa di RSUPNCM. Melalui metode convenient sampling dari 49 subjek orang
Indonesia berusia 19-49 tahun dengan kedua mata normal, dilakukan pengukuran
amplitudo dan latensi gelombang berdasarkan rekomendasi ISCEV. Pengukuran
meliputi gelombang N1 dan P1 pada ring 1 sampai 5. Terdapat perbedaan signifikan
nilai standar normal pemeriksaan elektroretinografi multifokal pada populasi orang
Indonesia dewasa secara statistik antara elektroda dengan amplitudo gelombang lebih
tinggi dan latensi lebih panjang pada elektroda Jet dan Dencott dibandingkan dengan
DTL. Elektroda DTL dan Jet dirasakan lebih nyaman daripada elektroda Dencott bagi
orang Indonesia dewasa normal untuk pemeriksaan elektroretinografi multifokal.
Elektroda DTL memberikan amplitudo gelombang yang paling rendah, latensi yang
apling pendek dan tingkat kenyamanan yang paling tinggi dibandingkan elektroda Jet
dan Dencott dalam pemeriksaan elektroretinografi multifokal pada orang Indonesia
dewasa normal.

ABSTRACT
To establish normal values of multifocal electroretinography (ERG) and to compare
the values and the comfort level using Jet, Dencott and DTL electrode in Indonesian
Adult. Through convenient sampling 49 normal Indonesian subjects between 19 and
49 yeras oldwere selected. Multifocal ERG amplitudes and implicit time values were
measured according to recommendation by the International Society for Clinical
Electrophysiology of Vision. Evaluation consisted of N1 and P1 wave in ring 1 to 5.
after the examination, all subjects filled in a questionnaire about comfort level,
adopted from the visual analog scale. We observed a statistically significant
difference in multifocal ERG normal values between electrode with higher wave
amplitudes and longer implicit time in Jet and Dencott electrodes compared to DTL
electrodes. Jet and DTL electrodes are more comfortable than Dencott electrodes for
Indonesian adults in multifocal ERG. DTL electrodes give the lowest wave amplitude
and the shortest implicit time and are the most comfortable electrode compared to Jet
and Dencott electrodes, in multifocal ERG in Indonesian adults.

 File Digital: 1

Shelf
 SP-Ika Citra Susanti.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2018
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 61 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-21-562883288 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20485509
Cover