UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Studi pendahuluan penentuan asam hipoklorit (HClO) menggunakan elektroda boron-doped diamond dalam larutan pH fisiologis = Preliminary study of hypochlorous acid (HClO) determination using boron-doped diamond electrode in physiological pH solution

Nadiatus Silmi; Ivandini Tribidasari Anggraningrum, supervisor; Endang Asijati Widijaningsih Ichsan, supervisor; Yuni Krisyuningsih, examiner; Iman Abdullah, examiner; Sunardi, examiner ([Publisher not identified] , 2019)

 Abstrak

ABSTRACT
HClO adalah salah satu jenis spesi oksigen reaktif (ROS). Konsentrasi HClO berlebih dalam tubuh dapat menyebabkan berbagai penyakit. Pada penelitian ini, perilaku elektrokimia HClO/ClO dalam larutan pH fisiologis dipelajari pada elektroda kerja BDD, Pt, dan Au sebagai studi untuk pengembangan sensor. Sel elektrokimia yang digunakan yaitu satu kompartemen menggunakan teknik voltametri siklik (CV) pada larutan NaClO 8,4 mM dalam larutan buffer fosfat 0,5 M. Sebelumnya, larutan standar NaClO ditetapkan konsentrasinya menggunakan metode titrasi iodometri. Berdasarkan karakterisasi CV, BDD menunjukkan nilai respon arus puncak reduksi HClO terbaik pada potensial +0,1 V (vs. Ag/AgCl) dengan pH optimum 6,6. Kurva kalibrasi linier (R = 0,9953) dapat dicapai  pada daerah konsentrasi NaClO dari 1,68 hingga 5,86 mM menggunakan elektroda BDD. Batas deteksi yang diperkirakan dapat dicapai adalah sebesar 0,46 mM dengan nilai relative standard deviation (RSD) yakni 4,2% setelah 6 kali pengukuran. Pengaruh oxygen reduction reaction (ORR) juga diamati pada puncak reduksi ClO di sekitar potensial -0,7 V hingga -0,9 V. Hasil CV menunjukkan, respon arus relatif berkurang dengan penambahan gas N2 di dalam larutan. Selain itu, pengaruh penambahan glukosa dan asam askorbat pada analit juga dipelajari. Hasil CV menunjukkan, penambahan glukosa dan asam askorbat tidak memberikan pengaruh yang signifikan terhadap pengukuran HClO.

ABSTRACT
HClO is a type of reactive oxygen species (ROS). The excessive production of HClO may cause various diseases. In this study, electrochemical behavior of HClO/ClO was studied using BDD, Pt and Au electrodes in physiological pH condition in order to develop sensors. The electrochemical measurements were performed in one-compartment electrochemical cell using cyclic voltammetry technique in a 0.5 M phosphate buffer solution containing of 8.4 mM NaClO. Iodometric titration method was used to determine the concentration of hypochlorite. Cyclic voltammograms (CVs) of NaClO standard solutions showed the best response at optimum pH of 6,6 at the potensial reduction of +0.1 V. A linear calibration curve (R2 = 0.9953) can be achievd in the concentration range of 1.68-5.86 mM NaClO with an estimated low detection limit of 0.46 mM. The relative standard deviation (RSD) value of 4.2% was obtained after 6 measurements. The effect of oxygen reduction reaction (ORR) was also observed at the peak of the reduction of ClO around -0.7 V to -0.9 V. CVs showed that the current response was relatively reduced by the addition of N2 gas in the solution. The addition of glucose and ascorbic acid had no significant effect on HClO measurements.

 File Digital: 1

Shelf
 S-Nadiatus Silmi.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 49 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-20-051226215 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20486680
Cover