UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Angka kontaminasi air susu ibu perah di Rumah Sakit Cipto Mangunkusumo dan faktor risiko yang memengaruhinya = Contamination rate of expressed breast milk in Cipto Mangunkusumo National Hospital and its affecting factors

Adhie Nur Radityo S; Rinawati Rohsiswatmo, supervisor; Klara Yuliarti, supervisor; Kaban, Risma Kerina, examiner; Teny Tjitra Sari, examiner; Yeva Rosana, examiner; Naomi Esthernita Dewanto, examiner (Fakultas Kedokteran Universitas Indonesia, 2019)

 Abstrak

Latar Belakang: Air susu ibu (ASI) merupakan asupan yang direkomendasikan pada semua bayi baru lahir. ASI pada bayi yang menjalani perawatan intensif diberikan dalam bentuk ASI perah (ASIP). Akan tetapi, berbagai penelitian menunjukkan bahwa serangkaian proses persiapan ASIP merupakan sumber kontaminasi dan penularan infeksi. Infeksi pada bayi baru lahir merupakan salah satu masalah serius yang belum terpecahkan dalam perawatan bayi baru lahir, termasuk pada Rumah Sakit Cipto Mangunkusumo (RSCM). Meskipun alur pengelolaan ASIP yang digunakan sudah sesuai dengan standar WHO, belum pernah dilakukan evaluasi terhadap kejadian kontaminasi ASIP sebelumnya.
Tujuan: Mengetahui angka kejadian kontaminasi ASIP di Rumah Sakit Cipto Mangunkusumo dan faktor-faktor yang memengaruhinya.
Metode: Dilakukan penelitian potong lintang terhadap 60 sampel ASIP di divisi Neonatologi Departemen Ilmu Kesehatan Anak (IKA) Fakultas Kedokteran Universitas Indonesia (FKUI) - Rumah Sakit Cipto Mangunkusumo (RSCM) pada bulan Desember 2018 hingga Januari 2019. Sampel penelitian merupakan ASIP yang didapatkan dari proses pemerahan oleh ibu dengan bayi yang dirawat di ruang perawatan Neonatal Intensive Care Unit (NICU) RSCM. Ibu dengan riwayat penyakit yang menular lewat ASI, mengalami mastitis, atau sedang mengonsumsi antibiotik dan probiotik dieksklusi dari penelitian. Dilakukan pemeriksaan kultur terhadap ASIP sebanyak dua kali yaitu pertama kali maksimal dua jam setelah ASI diperah dan kedua kali setelah disimpan di lemari pendingin dengan suhu <4oC selama 48 jam, selesai dilakukan pemrosesan dan siap diberikan pada bayi.
Hasil: Didapatkan hasil angka kontaminasi ASIP di NICU RSCM adalah sebesar 66,67%. Profil kuman terbanyak sebagai kontaminan ASIP di NICU RSCM adalah Staphyloccocus epidermidis (ASIP setelah diperah 46,7%, ASIP sebelum pemberian 40%), Acinetobacter baumanii (ASIP setelah diperah 18,3%, ASIP sebelum pemberian 16,7%) dan Staphylococcus haemolyticus (ASIP setelah diperah 13,3%, ASIP sebelum pemberian 6,7%). Faktor risiko yang berpengaruh terhadap kontaminasi ASIP di NICU RSCM diantaranya adalah tindakan cuci tangan ibu sebelum memerah ASI dan penggunaan masker oleh petugas saat memproses ASIP untuk bayi.

Background: Breast milk is the recommended nutrient for every newborn. Newborn in neonatal intensive care unit is also provided in form of expressed breast milk. However, various studies have shown that expressed breast milk preparation is prone to contamination and infection transmission. Infection in newborn is a serious problem which has not been solved in newborn care, including in Cipto Mangunkusumo National Hospital (CMH). In spite of its expressed breast milk process correspond with World Health Organization guideline, evaluation has never been thouroughly done for expressed breast milk contamination rate.
Objective: To investigate expressed breast milk contamination rate in Cipto Mangunkusumo National Hospital and its affecting factors
Method: Cross sectional study was done to 60 expressed breast milk samples in Neonatology division, Child Health Department, Faculty of Medicine Universitas Indonesia (FKUI) - Cipto Mangunkusumo National Hospital (CMH) on December 2018 to January 2019. Samples for the study were expressed breast milk taken from mother whose baby was admitted to Neonatal Intensive Care Unit (NICU) of CMH. Mothers with breast milk transmission infection, having mastitis, or consuming antibiotic or probiotic were excluded from the study. Culture from samples was done two times, the first time was at maximum of two hours after breast milk was expressed and the second time was after the breast milk had been stored in freezer with temperature below 4o Celsius for 48 hours, processed, and ready to be taken by newborn.
Result: It is shown that the contamination rate of expressed breast milk in NICU of Cipto Mangunkusumo Hospital was 66,67%. Most prevalent bacteria for expressed breast milk contaminant were Staphylococcus epidermidis (1st sampling 46,7% , 2nd sampling 40%), Acinetobacter baumanii (1st sampling 18,3%, 2nd sampling 16,7%), and Staphylococcus haemolyticus (1st sampling 13,3%, 2nd sampling 6,7%). Risk factors affecting expressed breast milk contamination in NICU of Cipto Mangunkusumo Hospital were mother handwashing before breast milk expression and the use of mask for officers processing expressed breast milk.

 File Digital: 1

Shelf
 SP-Adhie Nur Radityo S.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T57676
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xv, 49 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T57676 15-24-67326465 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20489588
Cover