UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pengaruh Penggunaan Citra MVCT Pada Distribusi Dosis Adaptif Tomoterapi Dalam Kasus Hepatoceluler Carcinoma = The Effect of Using Image on Tomotherapys Adaptive Dose Distribution in The Case of Hepatoceluller Carcinoma

Fira Rosalina; Mussadiq Musbach, supervisor; Supriyanto Ardjo Pawiro, supervisor; Djarwani Soeharso Soejoko, examiner; Dea Ryangga, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019)

 Abstrak

ABSTRAK
Verifikasi posisi pasien digunakan untuk memastikan bahwa posisi pasien telah sesuai dengan posisi perencanaan sehingga persebaran dosis yang diterima target sesuai dengan dosis yang direncanakan dalam adaptif planning. Penelitian ini bertujuan untuk mengevaluasi perbandingan distribusi dosis yang dihasilkan antara registrasi citra MVCT dan KVCT dengan maupun tanpa koreksi posisi secara otomatis serta mengevaluasi PTV margin yang digunakan dalam perencanaan maupun penerapan yang dilakukan dalam perlakuan terapi. Verifikasi posisi yang digunakan dalam registrasi citra MVCT dengan citra KVCT terdiri dari koreksi posisi dengan sumbu-X, Y, Z dan Roll pada target tumor. Pada penelitian ini digunakan citra MVCT dari 9 pasien Hepatocellular Carcinoma dengan perlakuan terapi dosis tinggi dalam 4-10 fraksi menggunakan HT di RSUPN Cipto Mangunkusuomo. Penelitian ini menghasilkan nilai deviasi sebesar 0,27% untuk HI dan 0,39% untuk CI, serta nilai Organ at Risk beberapa organ yang masih dalam batas aman. Nilai PTV margin yang dihasilkan antara perencanaan maupun perlakuan terapi memiliki kesetaraan. Berdasarkan hasil yang diperoleh pada penelitian menunjukan dengan adanya pergeseran dari verifikasi posisi maupun PTV margin dapat mempengaruhi persebaran dosis yang diterima target tumor.

ABSTRACT
Position verification before the treatment is used to ensure the accordance actual position to the planning position, so the dose distribution received by the tumor target will be in agreement with the planned dose in adaptive planning. The aim of this study was to evaluate the comparison from the dose distribution resulted from MVCT and KVCT image registration with and without automatic position correction as well as evaluating the PTV margin used in planning and implementing the treatment. The position verification used consists of position correction performed with adjustment in four HT degree of freedom (lateral, longitudinal, vertical and rotational direction). Nine MVCT patient images with Hepatocellular Carcinoma were used with high dose therapy in 4-10 fractions using HT at Cipto Mangunkusuomo Hospital. This study resulted in a deviation value of 0.269% for HI and 0.390% for CI, as well as the value of Organ at Risk which is still within safe limits. The PTV value of the margin produced between planning and treatment has equality. Based on the results obtained in the study showed that with a shift from verification of position and PTV margin can affect the distribution of the dose received by the target tumor.

 File Digital: 1

Shelf
 S-Fira Rosalina.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 48 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-45270155 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20491379
Cover