Faktor-faktor risiko yang berpengaruh terhadap keterlambatan proyek pembangunan gardu induk = Risk factors in substation construction project / Hartono

Hartono; Chairul Hudaya, supervisor; Rudy Setiabudy, examiner; Budi Sudiarto, examiner; Iwa Garniwa M.K., examiner ([Publisher not identified] , 2019)

 Abstrak

ABSTRAK
Gardu induk merupakan salah satu komponen utama dalam sistem ketenagalistrikan. Peranannya sangat vital dalam penyaluran energi listrik. Dalam proses pembangunan gardu induk, seringkali terjadi keterlambatan yang mengakibatkan kerugian. Penelitian ini bertujuan untuk mendapatkan respon terhadap faktor-faktor risiko yang berpengaruh pada waktu pelaksanaan, sehingga bisa dilakukan mitigasi dini agar keterlambatan dapat dihindari. Metode yang dilakukan adalah interview dengan para pelaksana pembangunan gardu induk dan divalidasi oleh para pakar. Hasil interview diolah secara statistik menggunakan perangkat lunak IBM SPSS 23. Variable penelitian sebanyak 52 faktor risiko. Hasil penelitian memperlihatkan terdapat 6 faktor risiko tinggi yang meliputi , 26 faktor risiko menengah, dan 5 faktor risiko rendah. Faktor-faktor risiko tinggi meliputi: perubahan desain engineering berkali-kali selama fase approval desain, keterlambatan pada submit dokumen approval, perubahan desain yang merubah kebutuhan alat dan sumber daya, kontradiksi risalah rapat selama proses desain, keterlambatan pengiriman pada peralatan utama, dan pencurian material di lapangan. Selanjutnya diberikan rekomendasi tindakan terhadap faktor-faktor risiko tinggi tersebut.

ABSTRACT
Substation is one of the main components in the electricity system. Its role is very vital distribute electrical energy. Delay in the process of constructing substations can result in losses. This study aims to get a response to the risk factors that influence the implementation time, so that early mitigation can be done so that delays can be avoided. The method used is an interview with the stake holder of the construction of the substation and validated by experts. The interview results were processed statistically using IBM SPSS 23 software. The research variables were 52 risk factors. The results showed that there were 6 high risk factors which included, 26 medium risk factors, and 5 low risk factors. High risk factors include: repeated engineering design changes during the design approval phase, delays in submitting approval documents, design changes that change equipment and resource requirements, minutes of meeting contradictions during the design process, delivery delays in major equipment, and material theft in the field. Furthermore, recommendations for action on these high risk factors are given.

 File Digital: 1

Shelf
 T55169-Hartono.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T55169
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resources
Deskripsi Fisik : xix, 123 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T55169 15-21-704236288 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20499477
Cover