Analisis akurasi skor HYCA pada evaluasi perdarahan Uterus Abnormal menggunakan Histeroskopi Office = Accuracy analysis of HYCA scores using Office Hysteroscopy to evaluate endometrial malignancy of abnormal uterine bleeding

Trisna Novika; Situmorang, Herbert, supervisor; Hartono Tjahjadi, supervisor; Eka Rusdianto, examiner; Yudianto Budi Saroyo, examiner; Achmad Kemal Harzif, examiner (Fakultas Kedokteran Universitas Indonesia, 2019)

 Abstrak

Latar belakang: Histeroskopi office merupakan sebuah alat penunjang
diagnostik terbaru yang makin marak digunakan dalam praktik sehari-hari.
Penggunaan alat ini memudahkan penegakkan diagnosis dan tatalaksana kasus
perdarahan uterus abnormal. Namun, sering kali ditemukan perbedaan interpretasi
temuan histeroskopi sehingga diperlukan keseragaman kriteria penilaian. Saat ini
telah dikenal sebuah sistem skoring temuan histeroskopi yang dikenal sebagai
skor hysteroscopy cancer (HYCA) untuk evaluasi patologi pada kasus perdarahan
uterus abnormal, terutama kasus keganasan endometrium.
Tujuan: (1) Mengetahui akurasi Skor HYCA sebagai metode skrining adanya
kanker endometrium pada perdarahan uterus abnormal. (2) Mengetahui
kesesuaian inter dan intraobserver dalam penilaian Skor HYCA pada evaluasi
perdarahan uterus abnormal menggunakan histeroskopi office.
Metode: Desain observasional cross sectional. Peneliti membandingkan skoring
HYCA dengan hasil histopatologi untuk menilai keakuratan skor dalam skrining
kasus karsinoma endometrium. Dilakukan uji kesesuaian intra dan inter observer
dalam menentukan skor HYCA dari rekaman video histeroskopi.
Hasil : Rekaman 87 video histeroskopi dengan 4 video dieksklusi karena tidak
dapat dinilai. Penelitian ini tidak terdapat pasien false negative, 18 pasien false
positive, dan sebelas kasus keganasan endometrium. Pasien dengan keganasan
memiliki median usia 57 tahun sesuai usia pasca menopause. Subjek dibagi
menjadi 2 kelompok yaitu pasaien dengan keganasan dan bukan keganasan
endometrium. Body mass index (BMI) pasien tidak berbeda secara bermakna pada
kedua kelompok yaitu BMI 25 kg/m2 pada pasien keganasan endometrium dan
IMT 24 kg/m2 pada kasus bukan keganasan. Nilai kesesuaian (Kappa)
intraobserver A 0.824 dan observer B 0.837. Nilai kesesuaian interobserver 0.732.
Sensitivitas 100%, spesifitas 75 %, akurasi 78.31% dan tingkat kesesuaian
terhadap hasil patologi dengan nilai Kappa 0.44.
Kesimpulan: Metode penapisan menggunakan skoring HYCA memiliki nilai
sensitivitas yang tinggi. Angka spesifitas yang rendah ini menunjukkan skoring
HYCA ini tidak dapat digunakan sebagai dasar diagnostik.

Background: Office hysteroscopy is one of the most frequent diagnostic tool
used in diagnosing and treating women with abnormal uterine bleeding.
Unfortunately, we often found interpretation findings variability that should be
standardized. Therefore there is scoring system, known as HYCA score, to
evaluate pathology findings in abnormal uterine bleeding, especially in
endometrial malignancy.
Aim: (1) To determine the accuracy of the HYCA score as a method of screening
for endometrial cancer in abnormal uterine bleeding. (2) To determine the inter
and intra-observer suitability in the HYCA Score assessment in the evaluation of
continued abnormal bleeding using hysteroscopic office.
Method: Observational cross sectional study. We compared the results of HYCA
score to histopathological findings to assess the accuracy of HYCA scores for
screening tool in endometrial carcinoma. Intra and inter-observer suitability tests
carried out for HYCA score assessment from hysteroscopy video recordings.
Result: There were 87 hysteroscopy video recordings from (bulan) to (bulan), 4
videos were excluded due to low quality videos. In this study, there weren't any
patients assessed as false negative, 18 patients were assessed as false positive and
11 patients were having endometrial malignancy. Median age was 57 years old,
corresponded to menopausal ages. Subjects than divided to malignant and non
malignant cases. Body mass index wes not significantly different between two
groups, 25 kg/m2 iand 24 kg/m2 respectively. The intraobserver (Kappa)
suitability value for observer A was 0.824 and B was 0.837. The interobserver
compatibility value is 0.732. Sensitivity was 100%, specificity was 75%,
accuration value was 78.31% and level of conformity to histopathology with
Kappa value was 0.44.
Conclusion : High sensitivity finding showed HYCA score as a good screening
tool rather than diagnostic tool showed by poor spesificity.

 File Digital: 1

Shelf
 SP-Trisna Novika.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xv, 58 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-21-923911482 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20501066
Cover