Pengaruh Densitas Penyemprotan Air terhadap Perambatan Kalor di Double-Skin Facade = Water Spray Density Influence in Water mist Spraying to Heat Transfer in Double-Skin Facade

Wiratama Dhaneswara Sungkono; Yulianto Sulistyo Nugroho, supervisor; Harinaldi, examiner; Budihardjo, examiner (Fakultas Teknik Universitas Indonesia, 2020)

 Abstrak

Tren penggunaan struktur facade di bangunan gedung sebagai upaya untuk menjadikannya sebagai Green Building kian meningkat. Di balik segala pengaruh positifnya terhadap konvervasi energi dan kenyamanan bangunan gedung, facade memiliki kecenderungan untuk meningkatkan risiko kebakaran di bangunan gedung, sehingga diperlukan sistem proteksi kebakaran aktif seperti water mist. Karya tulis ini bertujuan untuk membahas beberapa permasalahan seputar kebakaran dalam ruang atau bangunan dengan fitur Double-Skin Facade yaitu pengaruh penyemprotan water mist terhadap pergerakan api dan asap di dalam rongga facade dan penyebaran temperatur di dalam rongga facade. Metode penelitian yang digunakan adalah metode simulasi dengan menggunakan software Fire Dynamic Simulator. Simulasi dilakukan dalam dua tahap yaitu simulasi tanpa water mist dan dengan water mist dengan variasi water spray density (Densitas Penyemprotan Air) 4,89 L/menit.m2, 5,67 L/menit.m2, 6,53 L/menit.m2 dan 7,3 L/menit.m2.  Hasil yang didapat dari kedua tahap simulasi tersebut berbentuk data kuantitatif berupa temperatur dan kecepatan aliran, dan data kualitatif berupa gambaran penyebaran asap dan api. Berdasarkan kedua tahap simulasi tersebut penulis kemudian dapat merangkum bahwa penyemprotan water mist pada rongga Double-Skin Facade berpengaruh terhadap penurunan temperatur dan perubahan arah dan besar kecepatan aliran pada rongga facade dan kenaikan temperatur kotak pembakaran. Untuk mengukur besaran kuantitatif pada water mist, penulis juga melakukan analisis terhadap hubungan nilai water spray density terhadap penurunan temperatur pada rongga facade. Hasilnya nilai water spray density berbanding lurus terhadap penurunan temperatur pada rongga.

The trend of the usage of the Facade structure in buildings as part of the effort of building a Green Building is rising. Despite every positive effect towards conserving energy and increasing comfort for the occupant of buildings, Facade tends to increase the risk of fire in buildings, therefore an active fire protection tools such as water mist is needed. This thesis aims to review several problems around the Fire Safety of the usage of Facade in buildings, such as the effect of water mist spraying into the facade cavity to the movement of fire and smoke in that particular area and to identify the temperature distribution both in the cavity and in the room. The main method that was used is simulating this phenomenon with Fire Dynamic Simulator. The simulation was conducted in two steps which were simulation without and with water mist with water spray density variation of 4,89 L/menit.m2,  5,67 L/menit.m2 , 6,53 L/menit.m2 , dan 7,3 L/menit.m2.The author's found out that spraying water mist into the facade cavity could decrease the temperature in the facade cavity and some parts of the room. Not only that but it also affected the direction and the value of the velocity both in the facade cavity and in the room. Another important thing is the relationship between water spray density and the decreasing of temperature were aligned.

 File Digital: 1

Shelf
 S-Wiratama Dhaneswara Sungkono.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2020
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 93 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 146-21-636836321 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20505948
Cover