UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Optimasi parameter waktu dan arus proses plasma electrolytic oxidation pada paduan AZ31 = Optimization of the time and current parameters of the plasma electrolytic oxidation process in AZ31 alloys.

Efrina Hidayati; Anawati, supervisor; Azwar Manaf, examiner; Ariadne Lakshmidevi Juwono, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020)

 Abstrak

Plasma Electrolytic Oxidation (PEO) merupakan pelapisan permukaan logam dengan plasma anodisasi untuk menghasilkan lapisan tahan karat dan keras. Sifat lapisan yang dihasilkan dikendalikan oleh parameter proses seperti arus dan waktu pembentukan. Proses PEO dilakukan dengan 2 variasi yaitu variasi waktu dan variasi arus dalam larutan 0,5 M Na3PO4. Pada variasi waktu, arus yang digunakan adalah 0,5 A dengan waktu 1, 3, dan 5 menit. Sedangkan pada variasi arus digunakan arus 0,2; 0,3; 0,4 A dan dilakukan pada waktu konstan selama 3 menit. Temperatur elektrolit dijaga tetap 30°C dan diaduk dengan magnetic stirrer dengan kecepatan konstan 300 rpm. Perubahan morfologi sebagai fungsi arus dan waktu diamati menggunakan scanning electron microscope dan energy dispersive X-ray spectroscopy (SEM-EDS). Analisis fasa dilakukan dengan X-ray Diffraction (XRD). Perubahan kekerasan diamati melalui uji kekerasan micro-Vickers. Perubahan sifat korosi diuji dengan metode electrochemical impedance spectroscopy (EIS) dan potentiodynamic polarization (PDP). Hasil karakterisasi menunjukkan fasa kristal yang terbentuk pada lapisan PEO adalah fasa Mg3(PO4)2 yang diidentifikasikan pada puncak 35°, 37°, 49° dan 62° pada pola XRD. Nilai kekerasan lapisan PEO yang terbentuk pada 1, 3 dan 5 menit masing-masing adalah 315,67; 427,67; dan 382,67 HV sedangkan pada arus 0,2; 0,3; dan 0,4 A diperoleh nilai kekerasan lapisan masing-masing sebesar 355; 421,67; dan 459 HV. Hasil uji polarisasi menunjukkan peningkatan ketahanan korosi yang ditunjukkan dengan berkurangnya rapat arus korosi. Semakin kecil rapat arus korosinya maka laju pembentukkan korosi semakin berkurang. Pada variasi waktu 1, 3 dan 5 menit nilai rapat arus korosinya adalah 3,24 x 10-5; 7,76 x 10-7; dan 1,11 x 10-6 A/cm2 sedangkan pada variasi arus 0,2; 0,3; dan 0,4 A nilai rapat
arus korosinya adalah 2,26 x 10-6; 3,12 x 10-6; dan 7,60 x 10-7 A/cm2. Hasil EIS menunjukkan bahwa nilai R1 semakin besar yang artinya ketahanan resistansi polarisasi semakin besar dengan meningkatnya waktu dan arus pembentukan. Pada variasi waktu 1, 3 dan 5 menit nilai R1 adalah 42,35; 564,7; dan 574,4 Ω.cm2 sedangkan pada variasi arus 0,2; 0,3; dan 0,4
A nilai R1 adalah 254,5; 169; 627,5 Ω.cm2 setelah dicelupkan selama 3 jam.

Plasma Electrolytic Oxidation (PEO) is a coating for metal surface by plasma anodization to produce corrosion resistant and hard coating. The resulting coating properties were controlled by process parameters such as formation current and time. The PEO process in this research uses 2 variation: time and current formation in 0,5 M Na3PO4 solution. At the time variation, the current used is 0,5 A with time of 1, 3 and 5 minutes. Whereas in the current variation used 0,2;0,3 and 0,4 A for 3 minutes. The electrolyte temperature was kept at 30 oC and stirred with a magnetic stirrer at 300 rpm. Morphological changes were investigated by using scanning electron microscope and energy dispersive X-ray spectroscopy (SEM-EDS). Phase analysis was performed by X-ray Diffraction (XRD). Hardness changes were observed using micro-Vickers hardness test. Changes in corrosion properties were investigated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization (PDP). The phases formed in the PEO layer is Mg3(PO4)2 which identified at the peaks of 35°, 37°, 49° and 62° in the XRD pattern. Hardness of AZ31 alloys at 1, 3 and 5 minutes was 315,67 HV, 427,67 HV and 382,67 HV whilte at currents 0,2;0,3 and 0,4 A is 355 HV, 421,67 HV dan 459 HV. The polarization test results showed an increase in corrosion resistance which is approved by the reduced corrosion current density. The smaller the corrosion current, the rate of corrosion formation decreases. At the time variation of 1, 3 and 5 minutes the value of the corrosion current density is 3,24 x 10-5, 7,76 x 10-7, and 1,11 x 10-6 A/cm2 whereas in the variation of current 0,2; 0,3; and 0,4 A the
corrosion current density is 2,26 x 10-6; 3,12 x 10-6; and 7,60 x 10-7 A/cm2. EIS results showed that the higher value of R1 means the greater the polarization resistance. At the time variation of 1, 3 and 5 minutes the value of R1 are 42.35. 564.7, 574.4 Ω.cm2 whereas in the current variation of 0,2;0,3 and 0,4 A the value of R1 are 254.5, 169, 627.5 Ω.cm2 after being immersed for 3 hours.

 File Digital: 1

Shelf
 Pdf-Efrina Hidayati.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 56 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-21-894621760 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20508992
Cover