UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Simulasi Monte Carlo pengukuran profile neutron pada linear accelerator varian iX keluaran berkas foton berenergi 15 MV menggunakan MCNPX versi 2.6.0 = Monte Carlo measurement simulation of neutron profile on varian iX 15 MV photon beam linear accelerator using MCNPX version 2.6.0

Nikita Ciamaudi; Supriyanto Ardjo Pawiro, supervisor; Akbar Azzi, supervisor; Djarwani Soeharso Soejoko, examiner; Dwi Seno Kuncoro Sihono, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020)

 Abstrak

Reaksi fotoneutron adalah salah satu reaksi inti yang terjadi pada kepala linac, baik pada linac berkas foton ataupun berkas elektron. Reaksi fotoneutron menghasilkan produk berupa neutron dengan tingkat energi tertentu. Penelitian ini bertujuan untuk mensimulasikan berapa besar dosis neutron yang mungkin diterima oleh pasien radioterapi saat proses radioterapi dengan pesawat linac Varian iX 15 MV lapangan 10 cm × 10 cm. Simulasi pengukuran dilakukan pada posisi isocenter kedalaman 1 cm – 15 cm untuk membentuk kurva PDD. Pengukuran off-axis pada permukaan fantom, 2 cm, 3 cm, dan 15 cm juga dilakukan agar dapat membentuk off-axis profile.
Verifikasi simulasi dilakukan dengan membandingkan data pengukuran berkas foton lapangan 30 cm × 30 cm dengan beam data commissioning (BDC) Varian iX 15 MV Rumah Sakit Siloam MRCCC. Hasil Penelitian menunjukkan nilai dosis posisi isocenter adalah 1,24 × 10-2 Sv Gy-1 pada permukaan fantom, 4,82 × 10-2 Sv Gy-1 pada kedalaman 2 cm, 1,25 × 10-1 Sv Gy-1 pada kedalaman 3 cm, dan 1,89 × 10-6 Sv Gy-1 kedalaman 15 cm. Namun, nilai dosis tertinggi terdapat pada posisi -2 cm kedalaman 2 cm, yaitu 2,05 × 100 Sv Gy-1. Pada posisi isocenter, nilai dosis tertinggi berada pada kedalaman 7 cm dengan nilai 2,70 × 10-1 Sv Gy-1.

Photoneutron reaction is one of the reactions that occur in the linac head, both in the photon and the electron beam. The reaction produces neutrons with a certain energy level. This study aims to simulate how much neutron dose that may be received by radiotherapy patients during the process of radiotherapy with Varian iX 15 MV 10 cm × 10 cm field. Measurement simulation is carried out at an isocenter position depth of 1 cm - 15 cm to create a PDD curve. Off-axis measurements on phantom surfaces, 2 cm, 3 cm, and 15 cm are also carried out to make an off-axis profile.
Verification is done by comparing 30 cm × 30 cm field measurement data with beam data commissioning (BDC) of MRCCC Siloam Hospital’s Varian iX 15 MV linac. The result showed the dose value of the isocenter position is 1,24×10−2 Sv Gy-1 on the phantom surface, 4,82×10−2 Sv Gy-1 at a depth of 2 cm, 1,25×10−1 Sv Gy-1 at a depth of 3 cm, and 1,89×10−6 Sv Gy-1 at a depth of 15 cm. However, the highest dose value is -2 cm in 2 cm depth, which is 2,05 × 100 Sv Gy-1. In the  socenter position, the highest dose value is 2,70×10−1 Sv Gy-1 in 7 cm depth.

 File Digital: 1

Shelf
 S-Nikita Ciamaudi.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xv, 46 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-99230024 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20510368
Cover