UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Analisis Kejadian Trombosis Dini Konduit Vena Pasca-Bedah Pintas Arteri Koroner dengan Teknik On-Pump dan Off-Pump Pada Populasi Non-Resisten Aspirin = Early Vein Graft Thrombosis Analysis after On-Pump and Off-Pump Coronary Artery Bypass Graft Surgery in Non-Resistant Aspirin Patients

Dimas Trisetyo Nugroho; Dudy Arman Hanafy, supervisor; Sugisman, supervisor; Pribadi Wiranda Busro, examiner; Yefta Moenadjat, examiner; Tamba, Riana Pauline, examiner; Mohammad Ilyas, examiner (Fakultas Kedokteran Universitas Indonesia, 2020)

 Abstrak

Latar belakang : Konduit vena lebih rentan mengalami trombosis dini dalam satu tahun pertama pasca bedah pintas arteri koroner sehingga meningkatkan risiko morbiditas maupun mortalitas. Penelitian ini bertujuan untuk meneliti ada tidaknya perbedaan kejadian trombosis dini konduit vena pascabedah pintas arteri koroner (BPAK) dengan teknik on-pump dan off-pump pada pasien non-resisten aspirin.
Metode : Dilakukan suatu studi kohort prospektif pada pasien yang menjalani operasi BPAK elektif di Rumah Sakit Jantung dan Pembuluh Darah Harapan Kita dari bulan September 2019 hingga September 2020. Penelitan ini membandingkan kejadian trombosis pada satu bulan pascabedah pada kelompok on-pump dan off-pump dengan menggunakan pemeriksaan MSCT, serta membandingkan nilai MGF dan PI pada kedua kelompok tersebut.
Hasil : Sebanyak 60 konduit vena dari 28 pasien yang menjalani BPAK dilibatkan dalam penelitian ini. Sebanyak masing-masing 30 konduit pada kelompok off-pump dan on-pump. Hasil penelitian ini menunjukan tidak ada perbedaan bermakna pada kejadian trombosis dini antara kedua kelompok. Kejadian trombosis dini pada BPAK on-pump sebanyak 13,3% dan pada BPAK off-pump 13,3% (p=1). Evaluasi nilai MGF dan PI juga menunjukan hasil tidak berbeda bermakna antara kedua teknik operasi maupun pada kelompok konduit yang paten atau oklusi.
Simpulan : Tidak ada perbedaan bermakna pada kejadian trombosis dini antara BPAK baik secara on pump maupun off pump

Introduction : Early thrombosis is more common in vein grafts and may occur within the first year after coronary artery bypass graft surgery and can increase morbidity and mortality rate. This study aims to establish whether there is a difference of the incidence of early thrombosis after on-pump and off-pump CABG in non-aspirin resistant patient population.
Method : Patients who undergone elective CABG surgery from September 2019 to September 2020 in single center was included in this prospective cohort study. This study compares the incidence of vein graft thrombosis at one month postoperative in both groups on pump and off pump using MSCT, and compares MGF and PI value of in on pump and off pump group also in patent and occluded vein grafts.
Results : A total of 60 vein grafts (30 on-pump and 30 off-pump) from 28 patients were analyzed in this study. There was no significant difference on the incidence of early vein graft thrombosis between two groups (13,3% in on pump vs 13,3% in off pump, p:1). MGF and PI value showed no difference in both techniques also no difference in patent group and occluded group
Conclusion : There is no significant difference in early vein graft thrombosis after on-pump or off-pump CABG.

 File Digital: 1

Shelf
 SP-Dimas Trisetyo Nugroho.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource (rdacarries)
Deskripsi Fisik : xiv, 53 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-21-323102897 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20512955
Cover