UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Analisis Implementasi Sistem Proteksi Kebakaran dan Sarana Penyelamatan Jiwa di Jakarta International Stadium Tahun 2022 = Analysis of the Implementation of Fire Protection System and Means of Egress at Jakarta International Stadium in 2022

Raja Alif Fathullah; Zulkifli Djunaedi, supervisor; Nia Dwi Handayani, examiner; Mila Tejamaya, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2022)

 Abstrak

Penelitian ini membahas implementasi dan analisisnya terkait sistem proteksi aktif dan pasif terhadap kebakaran kebakaran serta sarana penyelamatan jiwa yang ada di Jakarta International Stadium pada tahun 2022. Penelitian ini menggunakan desain penelitian deskriptif analitik dengan menggunakan metode semi-kuantitatif. Berdasarkan hasil penelitian, diperoleh tingkat kesesuaian keseluruhan implementasi yang menunjukkan nilai sebesar 77,79% pada Existing result dan dikategorikan “Cukup (C)”. Selain itu diperoleh pula nilai pada Proyecting result sebesar 84,65% yang dikategorikan "Baik (B)". Hasil ini menunjukkan bahwa implementasi yang ada dianggap cukup mampu untuk mempertahankan konstruksi bangunan selama kebakaran terjadi, memberikan pertahanan pada bangunan untuk mencegah penyebaran api dan asap, melakukan pendeteksian, penginformasian, dan pemadaman api kebakaran, serta mampu untuk menyediakan sarana dan rute jalan keluar dan meminimalisir adanya hambatan yang dapat berdampak pada total waktu evakuasi penghuni hingga mencapai eksit pelepasan dan titik berkumpul sementara.

This study discusses the implementation and analysis of active and passive fire protection systems and means of egress at the Jakarta International Stadium in 2022. This study uses a descriptive analytic research design using a semi-quantitative method. Based on the results of the study, the overall level of conformity of the implementation showed a value of 77.79% in the Existing result and was categorized as "Enough (C)". In addition, the score on the Projecting Result was 84.65% which was categorized as "Good (B)". These results indicate that the existing implementation is considered capable of maintaining building construction during a fire, providing defense to the building to prevent the spread of fire and smoke, detecting, informing, and extinguishing fires, and being able to provide means and egress routes and minimize obstacles that can impact the total evacuation time of occupants until they reach the release exit and assembly point.

 File Digital: 1

Shelf
 S-Raja Alif Fathullah.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2022
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource (rdacarries)
Deskripsi Fisik : xix, 238 pages : illustration + appendix