Pengaruh active fire protection systems terhadap kehandalan bangunan dalam mencegah terjadinya bahaya kebakaran pada bangunan perhotelan di DKI Jakarta

MGS A. Rachman Putra; Irdham Alamsyah, supervisor (Fakultas Teknik Universitas Indonesia, 2001)

 Abstrak

The paper reviews the standard ot' design and installation of the Active Fire Protection
Systems for hotel buildings to minimize tire risk. When a tire occurs, active
protection system is necessary that pinpoints its location. Once detected, the first line
of defense against tire is a sprinkler system or other active tire protection systems.
Active Fire Protection Systems are detectors & alarm systems, automatic sprinkler
systems, risers, extinguishing systems, and smoke control, all of which is aimed to
solve the problem of fire damage.
ln major cities around the world especially in Jakarta, hotel buildings have been, are
and will be designed and built to provide safe and comfortable space for human life
and various activities. The fire risk is inherent in the building itself and it is of utmost
importance to eliminate or keep this risk and its consequences as small as possible.
On December 3 lst, 1986 a tire occurred in the Dupont Plaza Hotel and Casino, San
Juan, Puerto Rico, lt happened because The Hotel did not have dispensary ot`the tire
protection system in each floor. When thc iirc came and burncd, the building could
not extinguish the tire because it did not have the needed tire detector and sprinklers
in place.
From 50 questionnaires sent to various hotel buildings in Jakarta, 30 responses were
received to be viable for in dept analysis. The result of analysis shows clearly that the
active fire protection .tyvtents are positively correlated in a linear manner to three of
the key active fire protection variables. The key variables influencing building
reliability in good design and 'installation standard. The threc variables are heat
detector, portable exting-uis/ter, and rzulomatic sprinkler. This research can bc used t0
control and measure the standard design and installation of the hotel buildings.

 File Digital: 1

Shelf
 T5606-MGS A Rachman Putra-full text.pdf :: Unduh

LOGIN required

 Kata Kunci

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T5606
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : [Place of publication not identified]: Fakultas Teknik Universitas Indonesia, 2001
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resources
Deskripsi Fisik : xi, 65 pages: illustration; 29 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T5606 15-19-355652778 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 96225
Cover