Penilaian Kekritisan Kasus Pemisahan Sistem Masa Lalu dalam Jaringan Terinterkoneksi Eropa = Assessment of the Criticality of Past System Split Cases in the European Interconnected Grid

Rayhan Hanif Oetomo; Abdul Halim, supervisor; Aji Nur Widyanto, examiner; Ruki Harwahyu, examiner (Fakultas Teknik Universitas Indonesia, 2022)

 Abstrak

Dalam jaringan interkoneksi Eropa, transisi energi telah memberikan tantangan besar di masa depan untuk sistem tenaga listrik. Meningkatnya jumlah transit daya besar dari turbin angin dan Photovoltaic (PV) harus ditangani. Sebagai keputusan untuk menghapus pembangkit listrik konvensional, seperti batu bara dan tenaga nuklir, generator sinkron dalam jaringan listrik dikurangi, yang bertanggung jawab atas stabilitas jaringan listrik yang saling terhubung dan cadangan sesaat. Namun demikian, pemisahan sistem atau system split adalah kasus bermasalah di mana jaringan yang saling terhubung membagi jaringan sinkron menjadi dua atau lebih sub-jaringan sinkron. Transfer daya yang terputus dapat menyebabkan frekuensi sistem jaringan naik atau turun dengan cepat di sub-jaringan tertentu. Akan ada risiko pemadaman listrik, jika tindakan penanggulangan yang tepat tidak dapat dilakukan tepat waktu. Baru-baru ini, European Network of Transmission System Operators (ENTSO-E) belum membuat spesifikasi untuk mencegah kasus perpecahan sistem seperti itu atau menjaganya pada tingkat yang dapat dikelola.Oleh karena itu, baru-baru ini ada dorongan untuk setidaknya menilai kekritisan perpecahan sistem masa lalu dalam jaringan interkoneksi Eropa. Penilaian perpecahan sistem di masa lalu, bagaimanapun, tidak menentukan seberapa besar kemungkinan perpecahan sistem dalam situasi tertentu. Tetapi penilaian setidaknya akan mengetahui seberapa terkendalinya kemungkinan perpecahan sistem yang masih dapat dikendalikan untuk interkoneksi dan apakah pemadaman sebagian atau seluruhnya dapat dihindari. Meskipun jaringan interkoneksi Eropa belum mengalami pemadaman total, kasus system split menjadi lebih umum. Tujuan dari tesis sarjana ini adalah untuk menyelidiki dan menilai secara kritis kasus-kasus system split di masa lalu pada jaringan interkoneksi Eropa dengan menggunakan metode penilaian yang diusulkan dari ENTSO-E. Kasus-kasus perpecahan sistem di masa lalu harus terlebih dahulu diteliti secara intensif untuk mengevaluasi apakah ada basis data yang cukup untuk evaluasi sesuai dengan metode yang diusulkan. Pada akhirnya, nilai Rate of Change of Frequency (RoCoF) selama naik atau turunnya frekuensi dan titik frekuensi terendah atau tertinggi setelah system split terjadi.

In the European interconnected grid, the energy transition has given major challenges in the future for electrical power systems. The increasing number of large power transits from wind turbines and Photovoltaic (PV) have to be handled. As a decision to phase out conventional power generation, such as coal and nuclear power, synchronous generators in the grid are being reduced, which were responsible for the stability of the interconnected grid and instantaneous reserve. Nevertheless, system split or system separation is a problematic case in which the interconnected grid splits a synchronous grid into two or more synchronous sub-grids. Interrupted power transfers can cause the grid's system frequency to rapidly climb or fall in specific subnetworks. There will be a risk of a blackout, if appropriate countermeasures are not able to be taken in time. Recently, the European Network of Transmission System Operators (ENTSO-E) has not made specifications to prevent such system split cases or to keep them at a manageable level.Hence, there has been recently a push to at least assess the criticality of past system splits in the European interconnected grid. The assessment of past system splits, however, does not determine how likely a system split is in certain situations. But the assessment will at least know how controllable a possible system split remains manageable for the interconnection and whether a partial or complete blackout can be avoided. Although the European interconnected grid has yet to experience a complete blackout, system split cases are becoming more common. This purpose of this bachelor thesis is to investigate and assess the critically of the past system split cases in the European interconnected grid using the proposed assessment method from the ENTSO-E. The past system split cases must first be intensively researched in order to evaluate if there are sufficient data bases for the evaluation according to the proposed method. In the end, the value of the Rate of Change of Frequency (RoCoF) during the rise or fall of the frequency and lowest or highest frequency point after the system split happened.

 File Digital: 1

Shelf
 S-Rayhan Hanif Oetomo.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2022
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 61 pages ; illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-23-63041976 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920516093
Cover