UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Sensor H2O2 Berbasis Electrochemiluminescence Menggunakan Elektroda Screen Printed Carbon Termodifikasi Nanopartikel Emas = Electrochemiluminescence-Based H2O2 Sensor using Screen-Printed Carbon Electrodes of Modified Gold Nanoparticles

Junjunan Muhammad Syukur; Ivandini Tribidasari Anggraningrum, supervisor; Muhammad Ridwan Solehudin, supervisor; Yoki Yulizar, examiner; Munawar Khalil, examiner; Yuni Krisyuningsih Krisnandi, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022)

 Abstrak

Deteksi hidrogen peroksida (H2O2) berhasil dikembangkan dengan metode luminol electrochemiluminescence (ECL) pada permukaan screen-printed carbon electrode (SPCE) yang dimodifikasi dengan partikel emas. ECL luminol diperoleh dari  oksidasi luminol menghasilkan spesies 3-aminoftalat tereksitasi yang kemudian berelaksasi dengan memancarkan intensitas cahaya. H2O2 bertindak sebagai ko-reaktan pada ECL luminol karena hasil oksidasi elektrokimia H2O2 pada permukaan elektroda menghasilkan radikal hidroksil (OH•), yang dapat meningkatkan oksidasi luminol dan akibatnya meningkatkan sinyal ECL luminol. Modifikasi dengan partikel emas di permukaan SPCE dilakukan karena partikel emas memiliki kelebihan yaitu; luas permukaan yang besar, konduktivitas yang sangat baik, dan aktivitas katalitik yang baik terhadap oksidasi H2O2 untuk menghasilkan radikal hidroksil (OH•) yang distabilkan oleh interaksi pertukaran elektron parsial. Teknik voltametri siklik yang digunakan untuk menghasilkan oksidasi H2O2 dan oksidasi luminol yang menghasilkan ECL menunjukkan hubungan linear (R2 = 0,9995) pada rentang konsentrasi H2O2 0,5 µM hingga 200 µM. Sensor yang dikembangkan menunjukkan hasil performa yang baik dengan batas deteksi sebesar 4,78 µM, dan dapat digunakan untuk mendeteksi sampel H2O2 dalam matriks susu dan air keran.

Hydrogen peroxide (H2O2) detection was successfully developed by electrochemiluminescence (ECL) luminol method at a screen-printed carbon electrode modified with gold nanoparticles (AuNPs-SPCE). The ECL detection mechanism follows the oxidation of H2O2 to hydroxyl radicals (OH•) acting as a co-reactant to increase the ECL signal by inducing oxidized luminol to produce an excited species of 3-aminophthalate then relaxes and emits a luminous intensity on the electrode surface. AuNPs was deposited to SPCE due to feature high surface area, excellent conductivity, and good catalytic activity towards H2O2 oxidation to produce hydroxyl radicals (OH•) which stabilized by partial electron exchange interactions. Cyclic voltammetry (CV) technique was used for the ECL measurements which showed liner relationship (R2 = 0.9995) in the range 0.5 to 200 µM of H2O2 concentrations. The developed sensor showed a good perform with an estimated detection limit of 4.78 µM, and applicable for real sample detection of H2O2 in milk and tap water.

 File Digital: 1

Shelf
 T-Junjunan Muhammad Syukur.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvii, 59 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T-pdf 15-23-63044227 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920518337
Cover