UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Perbandingan Distribusi Dosis Pada Planning Klinis Dan Planning Menggunakan Konsep Definite Target Volume (DTV) pada Teknik Radioterapi Stereotaktik = Comparison Of Dose Distribution In Clinical Planning And Dose Plan Using The Concept Of Definite Target Volume In Stereotactic Radiotherapy Techniques

Ardian Widi Handoko; Supriyanto Ardjo Pawiro, supervisor; Arie Munandar, supervisor; Dwi Seno Kuncoro Sihono, examiner; Djarwani Soeharso Soejoko, examiner; Susworo, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022)

 Abstrak

SBRT adalah salah satu metode dalam radioterapi dengan menggunakan fraksi yang sedikit namun memiliki efek samping berpotensi menghasilkan wilayah hostpsot. Diusulkan volume target baru, yaitu Definie Target Volume (DTV). DTV memiliki probabilitas tinggi dimana jaringan target berada. DTV ditentukan melalui probabilitas okupansi dan kontraksi margin. DTV akan menjadi target prioritas dan PTV-crop diberlakukan seperti PTV pada perencanaan klinis. Optimisasi DTV dilakukan dengan eksplorasi dosis secara maksimum namun dengan membatasi dosis ke bagian OAR. Berdasarkan perencanaan, pada volume DTV kasus HCC, peningkatan 𝐷𝑚𝑎𝑥 tertinggi mencapai 187,3% dengan rata-ratanya 124,98% ± 29,02%. Untuk volume PTV-crop, rata-rata peningkatan 𝐷𝑚𝑒𝑎𝑛 adalah 103,84% ± 4,69%. Peningkatan 𝐷𝑚𝑎𝑥-DTV kasus serviks mencapai 138,49% dan rata-ratanya 116,80% ± 13,19%. Pada PTV-crop, rata-rata peningkatan 𝐷𝑚𝑒𝑎𝑛 serviks 101,89% ± 5,58%. Pemberian dosis yang besar pada target DTV akan berkaitan dengan peningkatan pada OAR. Peningkatan dosis OAR-HCC sebesar 106,93% ± 5,57% dan OAR-serviks sebesar 101,18% ± 1,87%. Hasil penelitian ini didapatkan dosis pada target DTV mengalami peningkatan yang cukup tinggi namun target PTV-crop mempunyai peningkatan dosis yang masih sesuai dalam standar untuk klinis. Selain itu OAR sekitar target meskipun dosis rata-ratanya meningkat, namun tidak terlalu signifikan dan masih dibawah konstrain.

SBRT is a method in radiotherapy using a small fraction but has side effects that have the potential to produce a host site. A new target volume is proposed, namely the Define Target Volume (DTV). DTV has a high probability of where the target network is. DTV is determined through the probability of occupancy and the contraction margin. DTV will be a priority target and PTV-crop is treated like PTV in clinical planning. Optimization of DTV is carried out by exploring the maximum dose but by limiting the dose to the OAR. Based on the plan, on the DTV volume of HCC cases, the highest 𝐷𝑚𝑎𝑥 reached 187.3% with an average of 124.98% ± 29.02%. For PTV-crop volume, the average 𝐷𝑚𝑒𝑎𝑛 increase to 103.84% ± 4.69%. The dose escalation in 𝐷𝑚𝑎𝑥-DTV for cervical cases reached 138.49% and the average was 116.80% ± 13.19%. In the PTV-crop, the average escalation in cervical 𝐷𝑚𝑒𝑎𝑛 was 101.89% ± 5.58%. Prescription of large doses to target DTV will be associated with an increase in OAR. The increase in the dose of OAR-HCC was 106.93% ± 5.57% and OAR-cervix was 101.18% ± 1.87%. The results of this study obtained that the dose on the DTV target had increased quite high, but the PTV-crop target had an increased dose that was still according to clinical standards. In addition, the OAR is around the target, although the average dose has increased, it is not very significant and is still under constraints.

 File Digital: 1

Shelf
 T-Ardian Widi Handoko.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 57 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T-pdf 15-23-16502142 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920520901
Cover