Gambaran Kualitas Udara dalam Ruangan PT. X, Jakarta Selatan Tahun 2023 = Overview of Indoor Air Quality at PT. X, South Jakarta in 2023

Davin Syauqi Adli Perdana Susanto; L. Meily Kurniawidjaja, supervisor; Mila Tejamaya, examiner; Angga Hadi Nugraha, examiner (Fakultas Kesehatan Masyarakat, 2022)

 Abstract

Skripsi ini membahas tentang Kualitas Udara dalam Ruangan (KUDR) di area kerja kantor pusat PT. X, yang ditinjau berdasarkan hasil pengukuran parameter KUDR yang meliputi parameter kimia (NO2, CO, CO2, PM10, TVOC, formaldehida), fisika (suhu, kelembaban, laju pergerakan udara, pencahayaan), dan mikrobiologi (total bakteri dan total kapang), serta dengan mendeskripsikan faktor KUDR yang ada di area kerja (sumber kontaminan, jalur kontaminan, ventilasi dan distribusi udara, pengguna ruangan). Penelitian menggunakan metode mixed-method dengan pendekatan deskriptif observasional. Analisis data dilakukan dengan membandingkan hasil pengukuran dengan syarat KUDR menurut Permenaker 5/2018 dan Permenkes 48/2016, dan dengan menganalisis faktor KUDR yang berperan. Didapatkan rata-rata konsentrasi CO2, TVOC, dan laju pergerakan udara tidak sesuai dengan setidaknya salah satu syarat KUDR. Faktor KUDR yang teridentifikasi dan berpotensi menjadi penyebab kondisi tersebut adalah kondisi ventilasi dan aktivitas pengguna ruangan. Perlu dilakukan penelitian lebih lanjut untuk mengukur kondisi polusi di luar gedung, performa ventilasi, dan keluhan serta gejala Sick Building Syndrome pada pekerja.

The focus of this study is to give an overview of Indoor Air Quality (IAQ) at PT. X office area. This study were conducted by analyzing the IAQ parameters measurement results which consist of chemical parameters (NO2, CO, CO2, PM10, TVOC, formaldehyde), physical parameters (temperature, humidity, ambient air velocity; illumination), and microbiological parameters (total bacteria and total mold), also by describing IAQ factors present in the work area (contaminant source, pathway, ventilation and air distribution, and occupant). The research used mixed-method with a descriptive and observational approach. Data analysis was carried out by comparing the IAQ measurement results with IAQ requirements according to Permenaker 5/2018 and Permenkes 48/2016, and by analyzing the IAQ factors that potentially play a role. This study revealed that the average CO2, TVOC, and ambient air velocity do not meet IAQ requirements which were potentially caused by poor ventilation and occupant activities. Further study is needed by measuring outdoor pollution, investigating ventilation performance, and collecting occupants’ complaints and Sick Building Syndrome symptoms

 Digital Files: 1

Shelf
 S-Davin Syauqi Adli Perdana Susanto.pdf :: Download

LOGIN required

 Metadata

Collection Type : UI - Skripsi Membership
Call Number : MK-pdf
Main entry-Personal name :
Additional entry-Personal name :
Additional entry-Corporate name :
Study Program :
Subject :
Publishing : Depok: Fakultas Kesehatan Masyarakat, 2022
Cataloguing Source LibUI ind rda
Content Type text
Media Type computer
Carrier Type online resource
Physical Description
Concise Text
Holding Institution Universitas Indonesia
Location Perpustakaan UI
  • Availability
  • Review
  • Cover
Call Number Barcode Number Availability
MK-pdf 14-24-47400519 TERSEDIA
Review:
No review available for this collection: 9999920525062
Cover