UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Praktik Kerja di Distribusi Farmasi PT Enseval Putera Megatrading DC I (Kalibrasi Data Logger Testo Saveris sebagai Pemantauan Suhu Otomatis pada Gudang A PT. Enseval Putera Megatrading) = Internship at Pharmaceutical Distribution PT Enseval Putera Megatrading DC 1 (Calibration of Data Logger Testo Saveris as a Automatic Temperature Monitoring at Warehouse A of PT. Enseval Putera Megatrading)

Gayatri Indah Pramesti; Harahap, Paskah Dwi Deborah, supervisor; Iskandarsyah, supervisor (Fakultas Farmasi Universitas Indonesia, 2023)

 Abstrak

Kalibrasi perangkat pemantau suhu otomatis sangat penting dalam industri farmasi untuk memastikan kondisi penyimpanan obat tetap optimal. Penelitian ini bertujuan untuk memastikan suhu pada ruang penyimpanan produk di Gudang A PT. Enseval Putera Megatrading sesuai dengan standar yang ditetapkan dan menganalisis hasil kalibrasi Data Logger Testo Saveris sebagai pemantau suhu otomatis. Penelitian dilakukan dengan metode kalibrasi menggunakan perangkat Testo 735-2 pada berbagai titik penyimpanan di gudang, termasuk Chiller FA, Chiller FB, Chiller FD, dan Cool Room A. Data suhu yang diperoleh dibandingkan dengan standar acuan yang telah dikalibrasi. Hasil kalibrasi menunjukkan bahwa Data Logger Testo Saveris mampu memberikan pembacaan suhu yang akurat dan konsisten pada semua titik penyimpanan yang diuji. Perangkat ini efektif dalam memantau dan menjaga suhu sesuai dengan parameter yang ditetapkan. Implementasi Data Logger Testo Saveris di Gudang A PT. Enseval Putera Megatrading terbukti dapat meningkatkan kualitas pengelolaan distribusi farmasi, mengurangi risiko kerusakan produk akibat suhu yang tidak sesuai, dan memastikan produk tetap aman hingga diterima oleh konsumen. Kalibrasi berkala disarankan untuk mempertahankan akurasi perangkat.

Calibration of automatic temperature monitoring devices is crucial in the pharmaceutical industry to ensure optimal drug storage conditions. This study aims to ensure that the storage temperature of products in Warehouse A of PT. Enseval Putera Megatrading meets established standards and to analyze the calibration results of the Testo Saveris Data Logger as an automatic temperature monitor. The study was conducted using the Testo 735-2 device for calibration at various storage points in the warehouse, including Chiller FA, Chiller FB, Chiller FD, and Cool Room A. The obtained temperature data were compared with calibrated reference standards. The calibration results show that the Testo Saveris Data Logger provides accurate and consistent temperature readings at all tested storage points. This device is effective in monitoring and maintaining temperatures according to the set parameters. Implementing the Testo Saveris Data Logger in Warehouse A of PT. Enseval Putera Megatrading has proven to enhance the quality of pharmaceutical distribution management, reduce the risk of product damage due to incorrect temperatures, and ensure product safety until it reaches consumers. Periodic calibration is recommended to maintain the accuracy of the device.

 File Digital: 1

Shelf
 PR-Gayatri Indah Pramesti2.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : PR-PDF
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Farmasi Universitas Indonesia, 2023
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : 54 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
PR-PDF 16-24-75872361 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920543721
Cover